-
...Single-phase Energy Meter Calibrator Procedure for calibration and testing of Single-Phase Energy Meter:-Give the connections as per the circuit diagram above. Apply 220V A.C to the pressure coil circuit by means of phase shifting transformer. Apply a load of 2 Amps by switching on the load. Note down the reading of two meters in a given period of time, say 2 minutes. Single Phase Power Energy Meter...
...Single-phase Energy Meter Calibrator Procedure for calibration and testing of Single-Phase Energy Meter:-Give the connections as per the circuit diagram above. Apply 220V A.C to the pressure coil circuit by means of phase shifting transformer. Apply a load of 2 Amps by switching on the load. Note down the reading of two meters in a given period of time, say 2 minutes. Single Phase Power Energy Meter... more
Brand Name:GFUVE
Model Number:GF112B - 2
Place of Origin:China
-
... Test 6. No-Load Test 7. Error at Lower Load Test 8. Error at Higher Load Test 9. Laser Printing 10. Chemical Sealing of the Meter Casing 11. Decision Stage. Main technical specifications of YCSS-101 Single Phase Standard Power Source Main feature: This
... Test 6. No-Load Test 7. Error at Lower Load Test 8. Error at Higher Load Test 9. Laser Printing 10. Chemical Sealing of the Meter Casing 11. Decision Stage. Main technical specifications of YCSS-101 Single Phase Standard Power Source Main feature: This more
Brand Name:GENY
Model Number:Automatic Test & Calibration line
Place of Origin:China
YCSS-101 Single Phase Automatic Test & Calibration Power Source Line
-
... Meter Multimeter Insulation Test FLUKE Insulation Multimeter Product Description Two powerful tools in one: The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter in a single ...
... Meter Multimeter Insulation Test FLUKE Insulation Multimeter Product Description Two powerful tools in one: The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter in a single ... more
Brand Name:Fluke
Model Number:Fluke1577 1587 1587FC 1587MTD
Place of Origin:USA
Fluke 1587FC Digital Clamp Meter Multimeter For Insulation Test 1587MTD
-
...judgment is only 0.3 seconds • Anti-drop protection for 1m on concrete surface • High-brightness LED display, with LED light switch on the test line (optional L9788-11 or L9788-10) • 200mA continuous test check • Capable of measuring AC/DC voltage,
-
...insulation grounding resistance tester for motor quality parameter testing and analyze test data General Information: Insulation resistance tester, also known as high-voltage insulation resistance tester, megohm meter, high-voltage megohm meter, digital high-voltage megohm meter, etc., in addition to taking into account dielectric discharge test, external voltage test, step voltage test, a variety of test
...insulation grounding resistance tester for motor quality parameter testing and analyze test data General Information: Insulation resistance tester, also known as high-voltage insulation resistance tester, megohm meter, high-voltage megohm meter, digital high-voltage megohm meter, etc., in addition to taking into account dielectric discharge test, external voltage test, step voltage test, a variety of test more
Brand Name:Sansion
Place of Origin:China
Certification:CE/CNAS/ISO9001
High Precision Hipot Insulation Resistance Meter for Motor Quality Parameter Testing
-
...range: 0-120% Output current:40A/20A/10A/5A/1A,Adjustment range: 0-120% 4.Output Phase:0-360 deg,Macro-adjustable phase:30°/shift, Micro-adjustable phase:0.1° Multiplex voltage separation PT is provided for each meter hanger carrier to ensure equal battery level of each meter station during electric meter counting test. Max.number meter test...
...range: 0-120% Output current:40A/20A/10A/5A/1A,Adjustment range: 0-120% 4.Output Phase:0-360 deg,Macro-adjustable phase:30°/shift, Micro-adjustable phase:0.1° Multiplex voltage separation PT is provided for each meter hanger carrier to ensure equal battery level of each meter station during electric meter counting test. Max.number meter test... more
Brand Name:Shengdi Electrical
Model Number:HS-6125
Place of Origin:China
HS-6125 Manually Operated Single Phase Dial Test Bench Energy Meter Counting
-
... and can withstand relative humidity of up to 95%. The Prepaid Electricity Meter is designed to operate in a wide range of temperatures, with an operating temperature range of -25℃ to +55℃. The Single Phase Prepaid Energy Meter comes equipped with a
-
...Insulation Resistance Meter Features 1) Small size and light weight, convenient for carrying 2) 1/23 digits LCD display, button for control backlight 3) Common batteries for power supply 4) 3 ranges voltage output rotation button for control output 5) Automatic switching of wide resistance test range 6) Stable and reliable test data 7) With high voltage output indication light Technical Index Resistance Test...
...Insulation Resistance Meter Features 1) Small size and light weight, convenient for carrying 2) 1/23 digits LCD display, button for control backlight 3) Common batteries for power supply 4) 3 ranges voltage output rotation button for control output 5) Automatic switching of wide resistance test range 6) Stable and reliable test data 7) With high voltage output indication light Technical Index Resistance Test... more
Brand Name:HNMC
Model Number:MCIM2500
Place of Origin:China
LCD 2500V Digital Insulation Resistance Meter Common Batteries
-
... resistance test, voltage test, DC current test,capacitance test Product introduction ZX2677F Series Digital Insulation Resistance Meter also known as , megohmmeter, high voltage insulation resistance tester, etc., for the insulation resistance test. The
-
...Insulating Resistance Tester Electrical Safety Test Equipment 1. Introduction RK2682 Insulation resistance tester is sepcial designed according to IEC, BS and UL standards, the test voltage has DC500 and DC1000V ranges, the insulation resistance (0.MΩ~2000MΩ) has been devided into 4 ranges: 2MΩ, 20MΩ, 200MΩ and 2000MΩ. The insulation resistance tester has been widely applied to test household appliance, insulation
...Insulating Resistance Tester Electrical Safety Test Equipment 1. Introduction RK2682 Insulation resistance tester is sepcial designed according to IEC, BS and UL standards, the test voltage has DC500 and DC1000V ranges, the insulation resistance (0.MΩ~2000MΩ) has been devided into 4 ranges: 2MΩ, 20MΩ, 200MΩ and 2000MΩ. The insulation resistance tester has been widely applied to test household appliance, insulation more
Brand Name:PEGO GROUP
Model Number:RK2682
Place of Origin:China
220V Electrical Testing Instrument IEC60335/IEC60065 500KΩ-2GΩ Insulating Resistance Test Meter
-
...Insulation Resistance Meter GB/T3048.5-2007 ZC-90 Series Insulation Resistance Meter Product description: Insulation resistance meter is an ideal instrument to test electrical insulating materials, wires and cables, anti-static resistance measurements as well as other electrical products insulation...
-
...Insulation Resistance Meter GB/T3048.5-2007 ZC-90 Series Insulation Resistance Meter Product description: Insulation resistance meter is an ideal instrument to test electrical insulating materials, wires and cables, anti-static resistance measurements as well as other electrical products insulation...
...Insulation Resistance Meter GB/T3048.5-2007 ZC-90 Series Insulation Resistance Meter Product description: Insulation resistance meter is an ideal instrument to test electrical insulating materials, wires and cables, anti-static resistance measurements as well as other electrical products insulation... more
Brand Name:HOOHA
Model Number:GB/T3048.5-2007
Place of Origin:Guangdong
GB/T3048.5-2007 Wire Cable Testing Machine Insulation Resistance Meter
-
... test of single phase, active or reactive energy meter, which also can be used as voltage source or current source. Highlights: High accuracy and stability Standard and source are integrated, it could be used as portable test system Wide output range, the
... test of single phase, active or reactive energy meter, which also can be used as voltage source or current source. Highlights: High accuracy and stability Standard and source are integrated, it could be used as portable test system Wide output range, the more
Brand Name:KRE
Model Number:KE8802
Place of Origin:China
Accuracy 0.1 Portable Test Equipment , Single Phase Standard Test Equipment
-
... Gloss Meter Introduction A glossmeter (also gloss meter) is an instrument which is used to measure specular reflection gloss of a surface.Gloss meter are mainly used in the surface gloss measurement for paint, plastic, metal, ceramics,granite tiles,
... Gloss Meter Introduction A glossmeter (also gloss meter) is an instrument which is used to measure specular reflection gloss of a surface.Gloss meter are mainly used in the surface gloss measurement for paint, plastic, metal, ceramics,granite tiles, more
Brand Name:CHN spec
Model Number:CS-380
Place of Origin:China
0 - 1000GU Test Range Degree Gloss Meter ISO 2813 Paints And Varnishes
-
...Single Phase Residential Electric Meter Prepaid Electricity Dispenser IP 54 Single Phase Enery Meter Keypad Residential Electric Meters Digital KWH Meter The CA168 is applied for a broad rang of STS prepayment applications, Thanks to an improved dynamic current range...
...Single Phase Residential Electric Meter Prepaid Electricity Dispenser IP 54 Single Phase Enery Meter Keypad Residential Electric Meters Digital KWH Meter The CA168 is applied for a broad rang of STS prepayment applications, Thanks to an improved dynamic current range... more
Brand Name:Calin
Model Number:CA168
Place of Origin:China
IEC Single Phase Residential Electric Meter Prepaid Electricity Dispenser
-
Single head wet gluten meter ISO 21415-2:2006 gluten content, gluten index and gluten water holding rate ST007AP Single head wet gluten meter ST007AP Gluten tester is used for the determination of gluten content, gluten index and gluten water holding rate...
-
...Insulation Tester Glass Heat Resistance Test Machine Glass Heat Insulated Test Bench Equipment Function Tests the thermal insulation performance of glass by simulating solar radiation. 1. Features a built-in four-sided rotating turntable; 2. Includes four insulating glass test samples: (1) Standard clear insulating glass (5mm clear glass + 15mm air gap + 5mm clear glass) (2) Single