Categories | Pure Water Equipment |
---|---|
Brand Name: | HYJB |
Model Number: | 5T |
Place of Origin: | Zhengzhou,China |
MOQ: | 1 set |
Price: | Negotiable |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 200 sets per month |
Delivery Time: | 7 days |
Packaging Details: | Wooden Case |
Water Temp: | 5-40℃ |
Core Components: | Engine, Motor |
Applicable Industries: | Garment Shops |
Type: | Water purification system |
Machinery Test Report: | Provided |
Automatic Industrial Commercial Machine Salt Free Water Softener System Softening Equipment
How it works
Reverse osmosis is a membrane separation technology driven by pressure with the help of the function of selective permeable (semi-permeable) membrane. When the pressure applied in the system is greater than the osmotic pressure of the inlet water solution, water molecules continuously permeate the membrane and flow into the central tube through the water production channel, and then flow out of the impurities in the water at one end, such as ions, organic matter, bacteria, viruses, etc.Is trapped at the water inlet side of the membrane and then flows out at the concentrated water outlet end, thereby achieving the purpose of separation and purification.
Parameter Table
Model | Water Making Ability | Inlet Caliber | Effluent Caliber | Blowdown alCer | Size(mm) | Power |
YSRO-0.5T | 0.5m3/h | DN20 | DN20 | DN15 | 1500×600×1500 | 1.3kw |
YSRO-1T | 1m3/h | DN25 | DN25 | DN20 | 1700×600×1500 | 2.1kw |
YSRO-2T | 2m3/h | DN32 | DN25 | DN20 | 2500×1000×1950 | 4.4kw |
YSRO-3T | 3m3/h | DN40 | DN32 | DN25 | 2500×1200×2150 | 4.5kw |
YSRO-5T | 5m3/h | DN50 | DN40 | DN32 | 2500×1350×2150 | 7.0kw |
YSRO-8T | 8m3/h | DN50 | DN50 | DN40 | 3500×1500×2150 | 11kw |
YSRO-10T | 10m3/h | DN50 | DN50 | DN40 | 3500×1600×2300 | 15kw |
Key Advantages
Environmental protection: reverse osmosis equipment is a physical
water treatment method, which does not require the use of chemical
agents, so it will not produce secondary pollution, nor will it
produce a large amount of waste water and waste residue, which is
environmentally friendly.
3. Strong reliability: The reverse osmosis equipment has high
stability and reliability, and can operate stably for a long
time.In addition, the maintenance and repair of reverse osmosis
equipment is relatively simple and easy to operate.
Maintance
Acid cleaning of reverse osmosis equipment
1. Turn off the chemical cleaning pump, turn off the inlet valve
and outlet valve of chemical cleaning, and let it stand and soak
for 1 hour. If the pollution is serious, the soaking time can be
extended.
2.Open the inlet valve and outlet valve of chemical cleaning, start
the chemical cleaning pump, and circulate the cleaning for 1 hour.
3. Check the pH in the bucket every ten minutes for three
consecutive times until there is no significant change in the pH
value for three consecutive times.
4.Wash with water that meets the inlet water index of reverse
osmosis. In order to prevent precipitation, the low-pressure
washing temperature is 20 ℃ until the pH and conductivity of the
water discharged from the cleaning outlet are close to the inlet
water index.
5. After cleaning, empty the cleaning bucket and filter, and rinse
them with clean water.
Product Display
![]() |