2 Wired Conventional Smoke Alarm 75dB-115dB For FM200 Gas Extinghuishant Control System

Categories Gas Extinguishing System
Brand Name: XHA
Model Number: XHA8015
Certification: CE
Place of Origin: China
MOQ: 1PCS
Price: negotiable
Payment Terms: T/T, Western Union
Supply Ability: 10000PCS/Month
Delivery Time: 3 Working days
Packaging Details: 30pcs/carton
Working Voltage: DC9-28V
Applications: Gas Extinghushant Control System, Fire Alarm System
Type: Conventional Smoke Alarm With Remote LED control function
Monitor Current: ≤800uA
Alarm Current: ≤20mA
Operating Humidity Range: 10% to 95% Relative Humidity(Non-condensing)
  • Product Details
  • Company Profile

2 Wired Conventional Smoke Alarm 75dB-115dB For FM200 Gas Extinghuishant Control System

2 Wired Conventional Smoke Alarm For FM200 Gas Extinghuishant Control System


Introduction


Conventional smoke detectors are a fundamental component of gas extighuishant and fire alarm systems, serving as the primary means of detecting the presence of smoke and initiating an alarm. These devices play a vital role in early fire detection, allowing building occupants to be alerted and evacuate the premises in a timely manner.


Key characteristics and functions of conventional smoke detectors include:


Smoke Sensing Technology:
Photoelectric Smoke Detectors: These detectors use a light source and a photosensitive sensor. Smoke particles entering the detection chamber scatter the light, causing it to reach the sensor and activate the alarm.


Alarm Initiation:
When smoke particles are detected, the smoke detector sends a signal to the fire alarm control panel, which then activates the overall fire alarm system, including audible and visual notification devices.


Conventional Configuration:
Conventional Smoke Detectors: These detectors are wired in a simple, non-addressable configuration, with multiple detectors connected to a single zone on the control panel.


Power Supply:
Conventional smoke detectors are typically powered by the fire alarm control panel, drawing their electrical power from the system's supervised circuits.


Maintenance and Testing:
Regular inspection, cleaning, and functional testing of conventional smoke detectors are essential to ensure their reliable operation in the event of a fire.


Parameters


Voltage ranges

20vdc to 27vdc (Nonpolarity)

Working Current≤40ma
Sound level

75dB-115dB (A) @3M

Material of coverAluminum
Operating Temp-10℃ to +55℃
Operating Humidity Range

10% to 95% Relative Humidity(Non-condensing)


Application in Addressable Fire Alarm System



Product Range


Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector


Service


1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.
5. Welcome sample order.


China 2 Wired Conventional Smoke Alarm 75dB-115dB For FM200 Gas Extinghuishant Control System factory
Send your message to this supplier
 
*From:
*To: Shenzhen Xinhe'an Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
Contact Us Quickly