Categories | Blood Sample Collection Tube |
---|---|
Certification: | FSC, ISO13485, CE, DOC |
Place of Origin: | China |
MOQ: | 30,000 Pcs |
Price: | Negotiable |
Payment Terms: | L/C, T/T, Western Union |
Supply Ability: | 10,000,000 Pieces Per Month |
Delivery Time: | 20-25 Days |
Packaging Details: | 100 Pcs/Tray, 18 Trays/Ctn |
Item Name: | Yellow Top Gel and Clot Activator Tube for Blood Collection 4ml |
Cap: | Yellow |
Additive: | Clot Activator |
Tube Material: | PET/Glass |
Label: | Paper/Transparent/UV Printing |
Tube Size: | 13*75mm, 13*100mm, 16*100mm |
Volume: | 2ml-10ml |
Shelf Life: | 2 Years (Glass), 1 Year (PET) |
Category: | Serum Blood Collection Tube |
Purpose: | To Obtain High Quality Serum Specimen |
Yellow Top Gel and Clot Activator Tube for Blood Collection 4ml
【Gel & Clot Activator Tube Description】
Gel and clot activator tube is used for blood serum biochemistry,
immunology and drug testing, etc. There uniformly sprays the
coagulant on the surface inside the tube, which will greatly
shorten the clotting time. As the imported separation gel from
Japan is pure substance, very stable in physicochemical property,
it can well stand high-temperature so that the gel will maintain a
stable status during the storage and transportation process. The
gel will get solidified after centrifugation and completely
separate serum from fibrin cells just like a barrier, which
effectively prevents the substance exchange between blood serum and
cells. Serum collection efficiency is improved and high-quality
serum will be obtained, thus it comes to more authentic
testing result. Keep the serum stable for more than 48 hours, no
obvious change will happen on its biochemical features and chemical
compositions, then the tube could be directly used in sampling
analyzers.
◆ Time for complete clot retraction: 20-25min
◆ Centrifugation speed: 3500-4000r/m
◆ Centrifugation time: 5min
◆ Recommended storage temperature: 4-25℃
【Gel & Clot Activator Tube Categories】
Category | Type | Additive | Cap Color | Tube Material | Tube Size | Test Item |
Serum Blood Collection Tube | Plain Tube | Plain | Glass/Plastic | 13*75mm | Clinical Biochemistry, Immunology and Serology Test | |
13*100mm | ||||||
16*100mm | ||||||
Pro-coagulation Tube | Clot Activator | Glass/Plastic | 13*75mm | |||
13*100mm | ||||||
16*100mm | ||||||
Gel & Clot Activator Tube | Gel & Coagulant | Glass/Plastic | 13*75mm | |||
13*100mm | ||||||
16*100mm | ||||||
Whole Blood Collection Tube | EDTA Tube | Sprayed K2EDTA / K3EDTA | Glass/Plastic | 13*75mm | Haematology Test (Blood Routine Examination) | |
13*100mm | ||||||
16*100mm | ||||||
ESR Tube | 3.8% Sodium Citrate Buffer (0.129mol/L), 3.2% Sodium Citrate Buffer (0.109mol/L) | Glass/Plastic | 13*75mm | Erythrocyte Sedimentation Rate Test | ||
13*100mm | ||||||
16*100mm | ||||||
Plasma Blood Collection Tube | Coagulation Tube | 3.2% Sodium Citrate Buffer (0.109mol/L) | Glass/Plastic | 13*75mm | Coagulation Function Test | |
13*100mm | ||||||
16*100mm | ||||||
Heparin Tube | Sodium Heparin / Lithium Heparin | Glass/Plastic | 13*75mm | Clinical Biochamistry for Emergency Treatment, Blood Rheology Test | ||
13*100mm | ||||||
16*100mm | ||||||
Glucose Tube | Sodium Fluoride & EDTA K2 / Sodium Fluoride & EDTA Na2 | Glass/Plastic | 13*75mm | Blood Glucose and Lactate Test | ||
13*100mm | ||||||
16*100mm |
【Gel & Clot Activator Tube Sequence】
Attentions:
【Gel & Clot Activator Tube Use Instructions】
Step 1: Choose the right specification pen-type blood collection needle and take off the white cover of the vacutainer needle.
Step 2: Screw the tube needle into the needle holder.
Step 3: Take off the color cover of the needle and choose the human proper vein to puncture. Insert the vacuum blood collection tube into the holder and press to puncture the tube stopper.
Step 4: After the vacuum in the tube used up, blood will stop flowing into the tube. Take out the vacutainer tube from the holder.
Step 5: Right after the blood tube taken out, turn it upside down 5-6 times to mix the blood and additive inside completely. Intense turning is strictly prohibited.
Step1: Screw tight the connection between tube needle and the soft pipe
to prevent leakage of vacuum or blood during the blood collection.
Step 2: Choose the human proper vein to puncture and blood flow could be
seen.
Step 3: Insert another side of the venous blood collection needle into the
tube stopper.
Step 4: When 0.5ml short of the rated blood volume in the final tube, take
out the needle from the vein. Take off the needle from tube after
blood in the soft pipe all flows into the blood draw tube.
Step 5: Right after the vacutainer needle taken out, turn the blood
sampling tube upside down 5-6 times to mix the blood and additive
inside completely. Intense turning is strictly prohibited.
Remark: The steps of correctly preparing high quality serum with Gel/Clot activator tube.
【Gel & Clot Activator Tube Related Products】
Venous Blood Collection Needle
Non-Vacuum Blood Collection Tubes
Mini Blood Collection Tube
![]() |