Home > Used Measuring & Analysing Instruments >

Digital Hydrogen Peroxide Analyzer RS485 Municipal Wastewater Treatment 800g

Categories Water Quality Analyzer
Brand Name: Daruifuno
Model Number: DUC2-HP-H
Certification: CE
Place of Origin: China
MOQ: Negotiable
Price: Negotiable
Product Name: Hydrogen Peroxide Transmitter
Product Model: DUC2-HP-H
Software Version: DRFN hydrogen peroxide Analysis software V1.0
Display Range: 0.01mg/L~100g/L
Relay Control: 2 settable SPST relays
Communication: RS485
Protection Grade: IP66
Current Output: two 0/4~20mA outputs
Operating Environment: 0~60℃
Shell Material: enhanced ABS
Weight: 800g
Power Consumption: 7W
  • Product Details
  • Company Profile

Digital Hydrogen Peroxide Analyzer RS485 Municipal Wastewater Treatment 800g


Digital Hydrogen Peroxide Transmitter RS485 For Municipal Wastewater Treatment 800g


DRFN’s digital hydrogen peroxide transmitter is a single parameter instrument, which is designed to measure hydrogen peroxide in water. It can connected to all DRFN’s digital hydrogen peroxide sensors to realize different measurement requirements.


Hydrogen Peroxide is widely used as a disinfectant in cooling towers and municipal wastewater treatment plants. H2O2 is an effective bactericide that does not form any harmful Disinfection By Products (DBP) like many chlorine products do. It decomposes naturally into oxygen and water and does not form a residual that hasto be removed from the treated water before it is released to the environment.


Features Of Hydrogen Peroxide Transmitter


  • Protection level IP66
  • Rich output configuration, analog or digital signals

  • single-parameter instrument

  • RS485 communication, support Modbus protocol
  • Provide wide-voltage AC or DC power supply mode
  • Support a variety of installation methods
  • Time and historical data recording functions
  • 128*64 black and white graphic dot matrix screen
  • 2 settable 0/4~20mA active current loop outputs
  • 2 settable SPST alarm relays
  • Menu password can be set


Applications Of Hydrogen Peroxide Transmitter


Drinking water, industrial wastewater, water supply system, urban sewage treatment



Product Parameters


Product Namehydrogen peroxide transmitter
Product Model

DUC2-HP-H

Software Version

DRFN hydrogen peroxide Analysis software V1.0

Display Range

0.01mg/L~100g/L

Resolution

0.01mg/L

Relay Control

2 settable SPST relays, the max. load 3A/250VAC

Analog Current Output

2 settable 0/4~20mA active current loop output max. load 1000Ω

Communication Method

Two-wire RS485 interface, MODBUS RTU; support JSON text data format

Display Screen

128*64 LCD, adjustable backlight mode, adjustable display rate

Time History/Data Record

Year/month/day/hour/min/second, record 14000 historical data, record interval can be set between 1~999 minutes

Maintenance Records

Last 100 times

Protection Grade

IP66

Operating Environment

0~60℃, relative humidity less than 95%

Storage Environment

-20~70℃, relative humidity less than 55%

Shell Material

Enhanced ABS

Dimensions

144*144*120mm (hole size 138*138 mm)

Mounting Method

Wall mounting, pipe clamping, panel installation

Power Supply

18~36V DC or 100~240V AC

Weight

800g

Power Consumption

7W

Electrical Interface

The back end of the instrument reserved 3 M12*1.5 gland, line diameter 3~6.5 mm


Matching Hydrogen Peroxide Sensors Introduction


  • Model: WP7
  • pH range: 2~11
  • Pressure range: 0~1 bar, no pressure surges and/or fluctuations
  • Temperature range: 0~45℃
  • Response time: T90 about 5~10 min
  • Flow rate: about 30 l/h, low flow-dependence
  • Material: PVC-U, stainless steel 1.4571
  • Connection: M12 male
  • Sensor with automatic temperature compensation

Type:

Measuring range:

ppm

Resolution:

ppm

Output signal:Power supply:Item number:
WP7H-M0c0.0~200.00.1

Modbus RTU

9~30 VDC

20~56 mA

3226130
WP7N- M0c0~200013226131


  • Model: WP10
  • pH range: 2~11
  • Pressure range: 0~1 bar, no pressure surges and/or fluctuations
  • Temperature range: 5~45℃
  • Response time: T90 about 8 min
  • Flow rate: about 30 l/h, low flow-dependence
  • Material: PVC-U, stainless steel 1.4571
  • Connection: M12 male
  • Sensor with automatic temperature compensation


Type:

Measuring range:

ppm

Resolution:

ppm

Output signal:Power supply:Item number:
WP10H-M0c0~2000.1

Modbus RTU

9~30 VDC

20~56 mA

3326350
WP10N-M0c0~200013326353
WP10L-M0c

0~2 %

(20000 )

0.001 % (10)3326351
WP10-20%-M0c

0~20 %

(200000 )

0.01 % (100)3326352

China Digital Hydrogen Peroxide Analyzer RS485 Municipal Wastewater Treatment 800g factory
Send your message to this supplier
 
*From:
*To: Suzhou Delfino Environmental Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
Contact Us Quickly