Product Name: | S100-β Rapid Test Kit |
Pack Size: | 25T |
Storage: | 4-30℃ |
Format: | Cassette |
Generic Name: | Central Nervous System Specific Protein |
Application In: | WWHS NIR-1000 Dry Fluoroimmunoassay Analyser |
Advantage: | High Sensitivity, High Accuracy |
【Product Name】S100.pdf
Diagnostic Kit for S100β protein(Immunochromatographic assay)
【Packing Specification】
25 Tests/kit
【Intended Use】
The kit is used for quantitative determination of S100β in human
whole blood, serum or plasma. Clinically, by detecting the expression of S100β
protein, we can judge the degree of brain injury and evaluate the
prognosis of patients.
【Test principle】
The Diagnostic Kit for S100β is a one-step chromatographic sandwich
immunoassay designed for the quantitative measurement of S100β. The
S100β antigen in the sample was first bound with the conjugated
compound of fluorescent labeled S100β monoclonal antibody, then
moved and combined with another S100β monoclonal antibody fixed on
the nitrocellulose membrane, and the double antibody sandwich
complex was formed at the detection line of the cellulose nitrate
membrane. The quantitative detection results were obtained by
NIR-1000 dry fluoroimmunoassay analyser.
【Components】
Name | Quantity | Component |
Test cards | 25 | The product consists of fluorescent pat (coated with fluorescently-labeled S100β monoclonal antibody), nitrocellulose membrane (coated with S100β monoclonal antibody ), absorbent paper and PVC soleplate. |
Sample diluent | 25 (200µL/ tube) | Tris-HCl buffer |
ID card | 1 | With specific stand curve file |
The components in different batches of kits cannot be used
interchangeably.
【Storage Conditions and Validity】
The kit should be stored at 4℃~30℃, out of direct sunlight. It is valid for 18 months. The test
card should be used within 15 minutes after unsealing under the
environment of 15℃~30℃ and 20% ~ 90% relative humidity. The sample
buffer is disposable and used immediately after opening the cap.
The production date, batch number and expiration date are shown in
the outer package of the product.
【Applicable Instrument】
NIR-1000 dry fluoroimmunoassay analyser produced by WWHS Biotech.
Inc.
【Sample Requirements】
【Test procedure】
【Reference interval】
S100β normal reference value is less than 0.20ng/mL. It is strongly
recommended that each laboratory should determine its own normal
and abnormal values.
【Interpretation of test results】
【Limitation of test method】
3. The triglyceride content in the sample does not exceed 15mg/mL, the hemoglobin content does not exceed 5mg/mL, the bilirubin content does not exceed 0.5mg/mL, the content of neuron-specific enolase does not exceed 200ng/mL, the content of glial fibrillary acidic protein does not exceed 5ng/mL, the content of IL-6 does not exceed 200pg/mL, the content of tumor necrosis factor does not exceed 200pg/mL, the content of albumin does not exceed 60mg/mL, the content of fibroblast growth factor does not exceed 20ng/mL, the cholesterol does not exceed 10mg/mL, the content of total protein does not exceed 120mg/mL, and the relative deviation of the measurement results does not exceed ±15.0%.
4. When S100β concentration of samples reaches 40.00ng/mL, there is no hook effect.
6. When RF concentration of samples is less than 2000IU/mL, relative deviation of test result is limited to ±15.0%.
7. For samples exceeding the linearity range, test cannot be conducted after dilution.
【Performance】
1. Limits of detection,No higher than 0.05ng/mL
2. Accuracy,The relative deviation to the target value is limited to ±15.0%.
【Note】
1. The kit can be used for in vitro diagnosis only.
2. Test card and buffer solution are single-use and they cannot be reused.
3. Please check the integrity and validity of the kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃ ~ 30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.
4. Take the test card out of the aluminum foil bag and carry out experiment in 15min. Do not place it in the air for a long time to avoid dampness.
5. It is required to strictly comply with the requirements for sample collection and storage. If the sample is turbid, please centrifuge and precipitate it before use.
6. The kit used should be disposed of as latent infective material,
and all samples, reagents and latent contaminants should be
disinfected and disposed of according to relevant local
regulations.
![]() |