Categories | Lithium Ion Battery Analyzer |
---|---|
Brand Name: | Neware |
Model Number: | CT-9004-5V5A-G4 |
Certification: | CE |
Place of Origin: | China |
MOQ: | 1 Unit |
Price: | USD negotiation per Unit |
Payment Terms: | T/T |
Supply Ability: | 100 Units Per Month |
Delivery Time: | 20 working days |
Packaging Details: | Carton Box , 585 - 575 - 130mm |
range1: | 0.1uA -150uA |
range2: | 140uA - 5mA |
range3: | 4.5mA - 150mA |
range4: | 140mA - 5A |
Voltage delta U: | 1mV |
Current delta I: | 100nA |
Neware 5V5A Lithium Ion Battery Analyzer GSM Pulse Dishcharge
Supported
43,000 Hours - 5 years
1 . Uninterrupted operation hours of 43000 hours , and equipment
still outputs and measures accurately .
2 . The core technologies are improvement on a new height , such as
8channel design , 0.02percent of FS accuracy, 1000Hz data
acquisition frequency , multi - range , supporting GSM and CDMA .
If you need highly accurate current output range to tell the subtle
difference of the battery material , but don’t need many pulse
tests , then CT - 9000 - 5V5A - 8CH is the better choice .
3 . Accuracy 0.02percent of FS , 4 auto - switch output ranges ,
400us pulse width, 1000Hz data record frequency , characterized
above and even more advanced features ,
4 . Neware BTS9000 is born to be the most advanced battery testing
system , it is the best choice for you to find the future battery
material .
GSM TEST / PULSE TEST / DCIR TEST
1 . BTS9000 is based on Neware sixth - generation testing system .
It's designed for battery material research , high - precision
tests, pulse charge/discharge tests , DCIR test , and cycle life
test .
2 . As the most cutting - edge equipment for battery material
research , BTS9000 comes with extremely high accuracy 0.02 percent
of FS , amazing hardware response speed - less than 100μs , wide
range of applications , high - speed testing data acquisition and
many other industry - proven characteristics , its your ultimate
choice for battery material research .
1000HZ
1 . We designed and shipped our sophisticated series which is
characterized with a max . data acquisition frequency of 1000Hz , a
minimum pulse width reaching 400us , an accuracy of 0.02percent of
FS and auto multi - current ranges enabled .
Project index | Parameter index | |
Voltage | Per Channel Voltage Range | 0 V~5V |
Min discharge voltage | 0.7 V - 0.5m cable , 5A discharge | |
Accuracy | 0.02percent of FS | |
Stability | 0.005percent of FS | |
Current | Stability | 0.005 percent of FS |
Charge | Charge Mode | Constant Current Charge , Constant Voltage Charge , Constant Current and Constant Voltage Charge , Constant Power Charge , Constant Resistance Charge |
End Conditon | Voltage , Current , Relative Time , Capacity , Energy , Power | |
Discharge | Discharge Mode | CCD / CPD / CRD / Pulse Discharge |
End Condition | Voltage , Current , Relative Time , Capacity | |
Pulse mode | Charge | CC , CP mode |
Discharge | CC , CP mode | |
Min pulse width | 400μs | |
Pulse number | Single pulse working step supports 16 different pulse segments | |
End Condition | Voltage , Relative Time | |
DCIR | Support for the calculation of the point of the DCIR | |
Cycle | Loop Measure Range | 65535 |
Max Steps Per Loop | 255 | |
Nested Loop | Nested loop Function , Max Support 3 Layers | |
Database | MySQL Database | |
A Means of Communication of Upper Machine | TCP / IP Protocol , 100M Ethernet | |
Data Output | EXCEL2003 , 2010 , TXT | |
Communication Interface | Ethernet Port | |
Per Unit Main Channels No. | 4 | |
Dimensions | WDH , 585 - 575 - 130mm |
![]() |