-
...Current Sensor Open Loop Current transducer For EV Battery Charger 1.Overview: ● Built-in Metrology & M-bus IC ● Max Measuring Current 100A ● Compact Size with Customized Design ● Stable Performance with Long Service Life ● Widely used for smart meter,smart grid,EV charger,monitoring device,circuit protection,machine equipment 2.Specification: Measuring Current...
...Current Sensor Open Loop Current transducer For EV Battery Charger 1.Overview: ● Built-in Metrology & M-bus IC ● Max Measuring Current 100A ● Compact Size with Customized Design ● Stable Performance with Long Service Life ● Widely used for smart meter,smart grid,EV charger,monitoring device,circuit protection,machine equipment 2.Specification: Measuring Current... more
Brand Name:IVY
Model Number:D129072
Place of Origin:Zhejiang
-
...Current High Frequency Current Sensor Closed Loop Current Transducer TBC1000LF high precision Closed Loop Hall Effect Current Sensor The TBC1000LF current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method ,with a galvanic isolation between primary and secondary circuit, the size of primary not affect test precision, no matter the location of primary in the hole of current
...Current High Frequency Current Sensor Closed Loop Current Transducer TBC1000LF high precision Closed Loop Hall Effect Current Sensor The TBC1000LF current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method ,with a galvanic isolation between primary and secondary circuit, the size of primary not affect test precision, no matter the location of primary in the hole of current more
Brand Name:TOKEN
Model Number:TBC1000LF
Place of Origin:CHINA
AC DC Pulse Current High Frequency Current Sensor Closed Loop Current Transducer
-
... are as follows: Basic Parameters: Rated Current: 100A RMS (at 25℃). Measurement Range: ±300A. Measuring Resistance: At 70℃ (with ±15V, ±25A.t max): Min. 54ohm, Max. 360ohm. Analog Output Current: 25mA. Turn Ratio: 1000. Accuracy (at 25℃
-
AHBC-LTA Closed-loop Transducer Measurement AC, DC, pulse and other complex current signals ● Excellent accuracy ● Low temperature drift ● Wide frequency bandwidth ● Optimized response time Technical Data
AHBC-LTA Closed-loop Transducer Measurement AC, DC, pulse and other complex current signals ● Excellent accuracy ● Low temperature drift ● Wide frequency bandwidth ● Optimized response time Technical Data more
Brand Name:Acrel
Model Number:AHBC-LTA
Place of Origin:Jiangsu, China
AHBC-LTA ISO Closed Loop Current Transducer Excellent Accuracy
-
LF1005-SSP16 LEM Open Loop Current Sensor ±1000A measurement range The LEM LF1005-SSP16 is a high-precision current sensor designed to measure AC and DC currents in various industrial applications. As part of the comprehensive LEM LF series, which ...
LF1005-SSP16 LEM Open Loop Current Sensor ±1000A measurement range The LEM LF1005-SSP16 is a high-precision current sensor designed to measure AC and DC currents in various industrial applications. As part of the comprehensive LEM LF series, which ... more
Brand Name:LEM
Model Number:LF1005-SSP16
Place of Origin:Switzerland
LF1005-SSP16 LEM Open Loop Current Sensor ±1000A measurement range
-
...open loop current sensor with up to 600A input,4.0V Output current transducer HBC-BS series hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents...
...open loop current sensor with up to 600A input,4.0V Output current transducer HBC-BS series hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents... more
Brand Name:Shinhom
Model Number:HBC-BS
Place of Origin:China
Open Loop Hall Effect Current Sensor , AC DC Current Transducer Good Linearity
-
...currents in high power and low voltage automotiveapplications with galvanic separation between the primary circuit (high power) and the secondary circuit (electronic circuit). The HAH1BVW family gives you the choice of having different current measuring ranges in the same housing 2.Features Ratiometric transducer ●Open Loop transducer...
...currents in high power and low voltage automotiveapplications with galvanic separation between the primary circuit (high power) and the secondary circuit (electronic circuit). The HAH1BVW family gives you the choice of having different current measuring ranges in the same housing 2.Features Ratiometric transducer ●Open Loop transducer... more
Brand Name:LEM
Model Number:HAH1BVW S/01
Place of Origin:CHINA
100A Car Battery Management Open Loop Transducer HAH1BVW S/01
-
... Type: Open Loop Response Time: 2.5 us Accuracy: 0.5 % Frequency Range: 400 kHz Operating Supply Voltage: 5 V Output Type: Digital, Analog Brand: ...
-
... noise, open loop operation and can be used in a variety of applications. The output signal is proportional to the strength of the magnetic field and can be used in applications such as motor control, position sensing, speed sensing, and current sensing.
... noise, open loop operation and can be used in a variety of applications. The output signal is proportional to the strength of the magnetic field and can be used in applications such as motor control, position sensing, speed sensing, and current sensing. more
Brand Name:Allegro MicroSystems
Model Number:A1125LLHLT-T
Place of Origin:Multi-origin
A1125LLHLT-T Current Transducer High Precision Quality And Reliability
-
...Open Loop Stepper Motor Driver For 57,86 Nema23 Nema34 Motor CNC Machine 1. Mechanical Specifications (unit: mm [inch]) 2. Electrical Specifications (Tj = 25℃/77℉) Parameters P860 Min Typical Max Unit Output current[PK] 0.5 - 7.2(6.0 RMS) A Supply voltage 24 36 75 Vac Pulse Voltage 4 5 28 Vdc Logic signal current...
...Open Loop Stepper Motor Driver For 57,86 Nema23 Nema34 Motor CNC Machine 1. Mechanical Specifications (unit: mm [inch]) 2. Electrical Specifications (Tj = 25℃/77℉) Parameters P860 Min Typical Max Unit Output current[PK] 0.5 - 7.2(6.0 RMS) A Supply voltage 24 36 75 Vac Pulse Voltage 4 5 28 Vdc Logic signal current... more
Brand Name:ZEROONR-Control
Model Number:P860/DM860
Place of Origin:Shenzhen, China
DM860 P860 2.4-7.2A Open Loop Stepper Motor Driver for Nema23 Nema34 Motors in CNC Machines
-
...Open Loop/Closed Loop Integrated Stepper Motors Driver Pulse/RS485 Control 0.18N.m 2Phase Nema11 DC20~30V 0.7/1.0A 1000PPR Lichuan Open Loop Closed Loop Integrated Stepper Motors Driver Pulse & RS485 Control | DC20–30V | Nema11–Nema24 Product Parameter Table Item Description Product Name Open Loop/Closed Loop Integrated Stepper Motors Driver Control Mode Open Loop / Closed Loop Motor Phase 2 Phase Voltage DC20–30V Current...
-
...Open loop sensor hall use the open loop hall direct testing principle to test direct current, alternating current and pulse current, the primary current is electrical isolation with secondary output signal. The output value can be customized. 2.The following is our detailed information of our hall effect sensor of open loop sensor hall ipn 5-10000A for dc ac and pc measurement Working Principle The magnetic flux produced by primary current...
...Open loop sensor hall use the open loop hall direct testing principle to test direct current, alternating current and pulse current, the primary current is electrical isolation with secondary output signal. The output value can be customized. 2.The following is our detailed information of our hall effect sensor of open loop sensor hall ipn 5-10000A for dc ac and pc measurement Working Principle The magnetic flux produced by primary current... more
Brand Name:grewin
Model Number:GWRCT
Place of Origin:Tianjin, China
hall effect sensor of open loop sensor hall ipn 5-10000A for dc ac and pc measurement
-
NACA.XXXL-S6/SP5VA Current Transducers Product Details product manual NACA XXXL-S6/SP5VA series current sensor is suitable for accurate measurement of AC, DC and pulse current isolation. The primary side and the secondary side are completely insulated dur...
NACA.XXXL-S6/SP5VA Current Transducers Product Details product manual NACA XXXL-S6/SP5VA series current sensor is suitable for accurate measurement of AC, DC and pulse current isolation. The primary side and the secondary side are completely insulated dur... more
Minimum Order Quantity:100
Payment Terms:T/T
Delivery Time:1-12 weeks
900A Current Transducers For DC Current Measurement
-
...Current Transducer DIP ZIP3 Current sensor Description : For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Closed loop (compensated) current transducer...
...Current Transducer DIP ZIP3 Current sensor Description : For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Closed loop (compensated) current transducer... more
Brand Name:LEM
Model Number:LA100-P
Place of Origin:CN
DIP ZIP3 LA100-P LEM 2V 2A Polymer Current Transducer
-
... circuit (electronic circuit). Applications: · Closed loop (compensated) multirange current transducer using the Hall effect · Unipolar voltage supply · Compact design for PCB mounting · Insulated plastic case recognized according to ...
... circuit (electronic circuit). Applications: · Closed loop (compensated) multirange current transducer using the Hall effect · Unipolar voltage supply · Compact design for PCB mounting · Insulated plastic case recognized according to ... more
Brand Name:LEM
Model Number:LTS15-NP
Place of Origin:PHILIPPINE
Integrated Circuit Chip LTS15-NP - LEM - Current Transducer
-
...Open Loop Cooling Tower For Chiller 1. Design condition of open type cooling tower: Inlet temperature 37°C, outlet 32°C; temperature difference 5°C; Wet bulb temperature 27°C, and atmospheric pressure 99400Pa. Specifications and dimensions are subject to change without notice. 2. Main features for open...
...Open Loop Cooling Tower For Chiller 1. Design condition of open type cooling tower: Inlet temperature 37°C, outlet 32°C; temperature difference 5°C; Wet bulb temperature 27°C, and atmospheric pressure 99400Pa. Specifications and dimensions are subject to change without notice. 2. Main features for open... more
Brand Name:Lanshuo
Model Number:125T
Place of Origin:China
Round Shape Industrial Open Loop Water Cooling Tower For Chiller
-
...open-loop Stepper Motor with driver 15 Kg.cm 1.8 Degree Explanation IO57 Minimum Value Typical Value Maximal Value Unit Continuous output current 1.0 - 5.6 A Power Supply Voltage (DC) 15 24/36 50 Vdc Control signal input current 6 10 16 mA Control signal input current...
...open-loop Stepper Motor with driver 15 Kg.cm 1.8 Degree Explanation IO57 Minimum Value Typical Value Maximal Value Unit Continuous output current 1.0 - 5.6 A Power Supply Voltage (DC) 15 24/36 50 Vdc Control signal input current 6 10 16 mA Control signal input current... more
Brand Name:Hetai
Model Number:57BYGH Series
Place of Origin:China
23 Nema Integrated Pulse Open Loop Stepper Motor With Driver 1.8 Degree
-
Open-air watertightness Split Core Current Transformer Black available be opened 5A/100A General Data: Operating temperature & humidity: 0 to S0'C(32-1220F),580%RH(No condensate) Storage ...