-
KFD2-HMM-16 HART MUX Primary Module 24 V DC Supply (Power Rail) 16-channel 24 V DC supply (Power Rail) HART field device input (revision 5 to 7) Up to 15 KFD0-HMS-16 HART MUX secondary modules can be connected Up to SIL 3 acc. to IEC/EN 61508 Manufacture...
KFD2-HMM-16 HART MUX Primary Module 24 V DC Supply (Power Rail) 16-channel 24 V DC supply (Power Rail) HART field device input (revision 5 to 7) Up to 15 KFD0-HMS-16 HART MUX secondary modules can be connected Up to SIL 3 acc. to IEC/EN 61508 Manufacture... more
Brand Name:p+f
Model Number:KFD2-HMM-16
Minimum Order Quantity:1
-
...HART MUX Secondary Module KFD0-HMS-16 16-channel No external power required HART field device input (revision 5 to 7) Used with HART MUX primary module KFD2-HMM-16 Up to SIL 3 acc. to IEC/EN 61508 General specifications HART MUX Secondary Module Functional safety related parameters Safety Integrity Level (SIL) SIL 3 Supply Connection via 14-channel flat cable from the KFD2-HMM-16 primary module HART...
...HART MUX Secondary Module KFD0-HMS-16 16-channel No external power required HART field device input (revision 5 to 7) Used with HART MUX primary module KFD2-HMM-16 Up to SIL 3 acc. to IEC/EN 61508 General specifications HART MUX Secondary Module Functional safety related parameters Safety Integrity Level (SIL) SIL 3 Supply Connection via 14-channel flat cable from the KFD2-HMM-16 primary module HART... more
Brand Name:PEPPERL FUCHS
Model Number:KFD0-HMS-16
Place of Origin:Germany
Pepperl Fuchs HART MUX Secondary Module KFD0-HMS-16 No external power required
-
... space. • Hot-Swap Design: Supports online module replacement without interrupting system operation, reducing maintenance time by 80%. • Intelligent Diagnostics: Integrated short circuit, disconnection, sensor failure, and power supply monitoring,
-
Power Supply Emerson KJ3221X1-BA1 DeltaV 8PT Analog HART Redundancy Module ROSEMOUNT HART INPUT MODULE Specifications: Condition: New Type: 8 Point Analog HART Input Module Make: Fisher Rosemount Emerson Series: DeltaV Model: KJ3221X1-BA1 VE40035S2B1...
-
...Rail Commercial Use And Home Use Power Supply Module Power Supply Module description: The DIN-PWS60 is a 60 Watt DC-NET Power Supply module designed to snap onto a standard DIN rail for installation in a wall-mount enclosure. DIN rail mounting enables modular to install ationalongside OKYSTAR DIN Rail lighting and automation control modules and other third-party DIN rail...
...Rail Commercial Use And Home Use Power Supply Module Power Supply Module description: The DIN-PWS60 is a 60 Watt DC-NET Power Supply module designed to snap onto a standard DIN rail for installation in a wall-mount enclosure. DIN rail mounting enables modular to install ationalongside OKYSTAR DIN Rail lighting and automation control modules and other third-party DIN rail... more
Brand Name:OKYSTAR
Model Number:DIN-PWS60
Place of Origin:China
1% Ripple Din Rail Lighting Control Module Power Supply For Commercial / Home
-
...HART Input module KJ3002X1-BA1 Emerson: DeltaV systems, dual-channel redundant security systems, redundant controllers, power modules, and I / O unit, Analog AI module, Analog AO module. Modular design allows flexible installation. A T- type DIN rail is all you need to mount the power/controller carrier into place. The I/O interface carrier plugs on to the power...
...HART Input module KJ3002X1-BA1 Emerson: DeltaV systems, dual-channel redundant security systems, redundant controllers, power modules, and I / O unit, Analog AI module, Analog AO module. Modular design allows flexible installation. A T- type DIN rail is all you need to mount the power/controller carrier into place. The I/O interface carrier plugs on to the power... more
Brand Name:Emerson
Model Number:KJ3002X1-BA1
Place of Origin:Germany
Emerson Delta V KJ3002X1-BA1 DeltaV Analog HART Input module KJ3002X1-BA1
-
...ensures reliable power distribution to IS modules, providing both durability and efficient power handling. Constructed from rugged polycarbonate moulding, it is designed for DIN rail or panel mounting to accommodate different installation environments. The
...ensures reliable power distribution to IS modules, providing both durability and efficient power handling. Constructed from rugged polycarbonate moulding, it is designed for DIN rail or panel mounting to accommodate different installation environments. The more
Brand Name:General Electric
Model Number:8724-CA-PS
Place of Origin:USA
8724-CA-PS GE Is Module Power Supply Carrier
-
...power rail Characteristics Small size Surface mount Low profile Operating temp: -40°C to 125°C Applications Isolated interface power supply for CAN, RS-485, RS-422, RS-232, SPI, I2C, lower-power LAN Industrial automation Process control Medical equipment PLC analog and digital I/O modules Isolated gate driver power supplies AC motor drives Uninterruptible power supplies...
...power rail Characteristics Small size Surface mount Low profile Operating temp: -40°C to 125°C Applications Isolated interface power supply for CAN, RS-485, RS-422, RS-232, SPI, I2C, lower-power LAN Industrial automation Process control Medical equipment PLC analog and digital I/O modules Isolated gate driver power supplies AC motor drives Uninterruptible power supplies... more
Brand Name:Shareway
Model Number:750315371
Place of Origin:Guangdong China
750315371 Push Pull Transformers 2.5kv Isolator For The USB Power Rail
-
...module as the control core, and the operation handle and remote control as the input means to provide power for the flat car. the battery is installed in the center of the rail track flat transfer car, and can also be installed in the front and rear of the
...module as the control core, and the operation handle and remote control as the input means to provide power for the flat car. the battery is installed in the center of the rail track flat transfer car, and can also be installed in the front and rear of the more
Brand Name:BEFANBY
Model Number:KPX
Place of Origin:Henan,China
Q235 45t Battery Powered Rail Transfer Car For Mold Plant
-
6EP1961-2BA31/6EP19612BA31 Category:PLC, HMI, SITOP, SOFTWARE & INVERTER Manufacturer:SITOP POWER Group:SIEMENS Automation 6EP4134-3AB00-0AY0 SITOP UPS1600 10A UNINTERRUPTIBLE POWER SUPPLY IN STOCK 6EP4134-3AB00-1AY0 SITOP UPS1600 10A USB UNINTERRUPTIBLE ...
-
ecer({videoId:"0HnRcZzZVik",videoId_local:"20210722_60f8c0e3d5b69.mov",idContainer:"#djanUfO"}) We can Supply Our Main Products as follow: 1> Solar Power System (Off Grid ,On Grid ,Hybrid) 2>Solar Panel 3>Inverter (Off Grid ,On Grid ,Hybrid) 4>Battery 5>...
-
...Power Supply Module Brand New In Original Description: Brand Honeywell Model Number TC-CCR013 Type I/O Module Lead Time 3-5 days Voltage 24V Warranty 1 Year High Level Analog Input /HART Input Module (16pt) – The High Level Analog Input Module supports both high level analog and HART inputs. Analog inputs are typically 4-20mA DC for both traditional and HART devices. HART data can be used for status and configuration. HART
...Power Supply Module Brand New In Original Description: Brand Honeywell Model Number TC-CCR013 Type I/O Module Lead Time 3-5 days Voltage 24V Warranty 1 Year High Level Analog Input /HART Input Module (16pt) – The High Level Analog Input Module supports both high level analog and HART inputs. Analog inputs are typically 4-20mA DC for both traditional and HART devices. HART data can be used for status and configuration. HART more
Brand Name:HONEYWELL
Model Number:TC-CCR013
Place of Origin:America
Honeywell TC-CCR Series Power Supply Module Brand New In Original
-
...Mux Rack Active Standby Power Supply 14-slots 2U Telephone Fiber Mux Rack Accessories Advantages: ► The configuration of active/standby power supply ensures uninterruptible operation of the system. ► Provide two power supplies (AC 220V, or DC -48V), enabling the system can work under many operating environments; ► Supporting simultaneous operation of several module type (module...
...Mux Rack Active Standby Power Supply 14-slots 2U Telephone Fiber Mux Rack Accessories Advantages: ► The configuration of active/standby power supply ensures uninterruptible operation of the system. ► Provide two power supplies (AC 220V, or DC -48V), enabling the system can work under many operating environments; ► Supporting simultaneous operation of several module type (module... more
Brand Name:E-link
Model Number:LNK-PR14-2A
Place of Origin:China
14 Slots 2U Telephone Fiber Mux Rack active standby power supply
-
...power supply applied imported power supply special driving chip and high precision and high temperature resistant electronic components, and adopts international advanced pulse width modulation(PWM) technology. It has short circuit, overload, over voltage,
...power supply applied imported power supply special driving chip and high precision and high temperature resistant electronic components, and adopts international advanced pulse width modulation(PWM) technology. It has short circuit, overload, over voltage, more
Brand Name:Coolmay
Model Number:CX6024
Place of Origin:China
DIN Rail 6.5A PLC Power Supply Module 90*60*32mm Over Heat Protection
-
... 61508 Technical Data Functional safety related parameters Safety Integrity Level (SIL) SIL 3 Supply Connection terminals 17+, 18- Rated voltage 20 ... 32 V DC typical at 100 mA Power consumption max. 3 W HART signal channels (non-intrinsically safe)
... 61508 Technical Data Functional safety related parameters Safety Integrity Level (SIL) SIL 3 Supply Connection terminals 17+, 18- Rated voltage 20 ... 32 V DC typical at 100 mA Power consumption max. 3 W HART signal channels (non-intrinsically safe) more
Brand Name:P+F
Model Number:KFD2-HMM-16
Place of Origin:Germany
SIL 3 HART Multiplexer Master KFD2-HMM-16
-
...MODULE Description Model 6ES7650-1AB61-2XX0 Brand SIEMENS DataSheet/Catalogue In PDF File Weight 5,500 Kg Condition Normal Description SIMATIC PCS7, red. AO8 HART MTA interface module for redundant interface for ET200M AI8-HART-BG 6ES7332-8TF01-0AB0, 8 channels, redundant power supply with fusing, LED displays, measuring range: 0-20 mA without HART, 4-20 mA with HART...
...MODULE Description Model 6ES7650-1AB61-2XX0 Brand SIEMENS DataSheet/Catalogue In PDF File Weight 5,500 Kg Condition Normal Description SIMATIC PCS7, red. AO8 HART MTA interface module for redundant interface for ET200M AI8-HART-BG 6ES7332-8TF01-0AB0, 8 channels, redundant power supply with fusing, LED displays, measuring range: 0-20 mA without HART, 4-20 mA with HART... more
Brand Name:SIEMENS
Model Number:6ES7650-1AB61-2XX0
Place of Origin:GERMANY
SIEMENS 6ES7650-1AB61-2XX0 SIMATIC PCS7,INTERFACE MODULE
-
...Mux/Demux module 1310~1610nm GEZHI 16-Channels Passive CWDM Mux/Demux was packaged in a ABS box LC/PC pigtailed over single Fiber. We designed GEZHI xWDM Series products to allow gradual, easy, logical and cost efficient expansion of network bandwidth using industry leading passive WDM technology. Main advantage of xWDM is its passive nature – cooling necessary or no power supply...
...Mux/Demux module 1310~1610nm GEZHI 16-Channels Passive CWDM Mux/Demux was packaged in a ABS box LC/PC pigtailed over single Fiber. We designed GEZHI xWDM Series products to allow gradual, easy, logical and cost efficient expansion of network bandwidth using industry leading passive WDM technology. Main advantage of xWDM is its passive nature – cooling necessary or no power supply... more
Brand Name:GEZHI or OEM
Model Number:16CH-CWDM Mux/Demux
Place of Origin:China
16 Channel CWDM Mux Demux
-
... 61508 Technical Data Functional safety related parameters Safety Integrity Level (SIL) SIL 3 Supply Connection terminals 17+, 18- Rated voltage 20 ... 32 V DC typical at 100 mA Power consumption max. 3 W HART signal channels (non-intrinsically safe)
... 61508 Technical Data Functional safety related parameters Safety Integrity Level (SIL) SIL 3 Supply Connection terminals 17+, 18- Rated voltage 20 ... 32 V DC typical at 100 mA Power consumption max. 3 W HART signal channels (non-intrinsically safe) more
Brand Name:P+F
Model Number:KFD2-HMM-16
Place of Origin:Germany
SIL 3 HART Multiplexer Master KFD2-HMM-16 16-Channel
-
...Module/Board,Power supply,Controller, etc.We maintains an inventory of new and obsolete parts utilized in all areas of the manufacturing and industrial sectors. Featured Brand: ● HONEYWELL ● AB ● OMRON ●SIEMENS ●SCHNEIDER ● ROSEMOUNT● ABB ● NOTIFIER ●MTL ● GE ●And many more ! MC-PLAM02 51304362-150 HONEYWELL LOW LEVEL AALOG MUX...
...Module/Board,Power supply,Controller, etc.We maintains an inventory of new and obsolete parts utilized in all areas of the manufacturing and industrial sectors. Featured Brand: ● HONEYWELL ● AB ● OMRON ●SIEMENS ●SCHNEIDER ● ROSEMOUNT● ABB ● NOTIFIER ●MTL ● GE ●And many more ! MC-PLAM02 51304362-150 HONEYWELL LOW LEVEL AALOG MUX... more
Brand Name:Honeywell
Model Number:MC-PLAM02
Place of Origin:USA
MC-PLAM02 51304362-150 Low Level Aalog Mux Model Honeywell PLC Module One Year Warranty
-
No power required AWG DWDM Modules GEZHI offers a full range of AWG products, including 50GHz, 100GHz and 200GHz AWG. Here we present the generic specification for the 40-channel 100GHz AWG MUX/DEMUX component supplied for use in DWDM system Features ...
No power required AWG DWDM Modules GEZHI offers a full range of AWG products, including 50GHz, 100GHz and 200GHz AWG. Here we present the generic specification for the 40-channel 100GHz AWG MUX/DEMUX component supplied for use in DWDM system Features ... more
Brand Name:GEZHI or OEM
Model Number:AAWG48
Place of Origin:China
No power required AWG DWDM Module