... Brand new Description Potential supply terminal, 24 V DC, with diagnostics Technical Data The EL9110 potential feed terminal with diagnostics enables the setup of different potential groups with the standard voltage 24 V DC. The supply voltage is ...
... Brand new Description Potential supply terminal, 24 V DC, with diagnostics Technical Data The EL9110 potential feed terminal with diagnostics enables the setup of different potential groups with the standard voltage 24 V DC. The supply voltage is ... more
Brand Name:BECKHOFF
Model Number:EL9110
Place of Origin:GERMANY
-
Electrical data Operating voltage[V] 18...30 DC; (cULus - Class 2 source required) Current consumption[mA] < 50 Sensor supply US Current rating per port[A] 0.1 Inputs / outputs Number of inputs and outputs Number of digital inputs: 16 Inputs Number of ...
-
...Io-Link Slave Module SDIOL-0HN0-M12 IP67 Remote I/O Module Product Description Decowell SD Series IP67 Remote I/O SDIOL-800N-M12 IO-Link Slave Module. The SD series products are high protection I/O modules from Decowell, up to IP67 protection level. The IP67 standard refers to the protection safety level. Bus I/O modules...
...Io-Link Slave Module SDIOL-0HN0-M12 IP67 Remote I/O Module Product Description Decowell SD Series IP67 Remote I/O SDIOL-800N-M12 IO-Link Slave Module. The SD series products are high protection I/O modules from Decowell, up to IP67 protection level. The IP67 standard refers to the protection safety level. Bus I/O modules... more
Brand Name:DECOWELL
Model Number:SDIOL-0HN0-M12
Place of Origin:China nanjing
High Protection Io-Link Slave Module IP67 PLC Remote IO Input Output Module
-
...IO-LINK MASTER MODULE Product details Model 1734-4IOL Brand PLC Description PLC 1734 Controller Datasheet/Catalogue PDF File Weight 0.5KG Condition Normal Product Description Flexibility:Connectivity to ControlNet, DeviceNet,EtherNet/IP and other open networks;Linear, star, and ring EtherNet/IP network topology;Supports IO-Link...
...IO-LINK MASTER MODULE Product details Model 1734-4IOL Brand PLC Description PLC 1734 Controller Datasheet/Catalogue PDF File Weight 0.5KG Condition Normal Product Description Flexibility:Connectivity to ControlNet, DeviceNet,EtherNet/IP and other open networks;Linear, star, and ring EtherNet/IP network topology;Supports IO-Link... more
Brand Name:PLC
Model Number:1734-4IOL
Place of Origin:USA
PLC 1734-4IOL IN-CABINET 4CHANNEL IO-LINK MASTER MODULE
-
SIEMENS 6ES7 147-5JD00-0BA0 | SIMATIC ET 200AL CM 4X IO-LINK 4XM12 *SHIP NOW* Email:miya@mvme.cn Product datasheet 6ES7147-5JD00-0BA0 SIMATIC ET 200AL CM 4X IO-LINK 4XM12 Model Type: Manufacturer(s)Siemens Model(s)Siemens Simatic S7 Additional Information ...
SIEMENS 6ES7 147-5JD00-0BA0 | SIMATIC ET 200AL CM 4X IO-LINK 4XM12 *SHIP NOW* Email:miya@mvme.cn Product datasheet 6ES7147-5JD00-0BA0 SIMATIC ET 200AL CM 4X IO-LINK 4XM12 Model Type: Manufacturer(s)Siemens Model(s)Siemens Simatic S7 Additional Information ... more
Brand Name:SIEMENS
Model Number:6ES7 147-5JD00-0BA0
Place of Origin:GERMANY
SIEMENS 6ES7 147-5JD00-0BA0 | SIMATIC ET 200AL CM 4X IO-LINK 4XM12 *SHIP NOW*
-
IO-Link communication interface + manifold board: Multi-protocol module + manifold board: Multi-pin plug connection + manifold block: Modbus-RTU protocol module + manifold board:
IO-Link communication interface + manifold board: Multi-protocol module + manifold board: Multi-pin plug connection + manifold block: Modbus-RTU protocol module + manifold board: more
Brand Name:NBSANMINSE
Model Number:FV-xxx-4-S12-IOL,FV-xxx-4-S12-MPL...
Place of Origin:CHINA
IO-Link communication interface + manifold board
-
Application Application I/O modules for field applications Daisy-chain function fieldbus interface Electrical data Operating voltage [V] 20...30 DC; (US ; to SELV/PELV) Current consumption [mA] 300...3900; (US) Protection class III Sensor supply US Max. ...
-
... CAT is the abbreviation of the prefix of Control Automation Technology. EtherCAT is a deterministic industrial Ethernet, which was originally developed by the German company Beckhoff. Automation usually requires shorter update times (or cycle times) for
... CAT is the abbreviation of the prefix of Control Automation Technology. EtherCAT is a deterministic industrial Ethernet, which was originally developed by the German company Beckhoff. Automation usually requires shorter update times (or cycle times) for more
Brand Name:KRONZ
Model Number:KA0032N
Place of Origin:Guangzhou,China
NPN Remote I/O Module 500V 32 Channels Digital Output Module 24VDC
-
... serial bus ◎Resolution: 240*320 ◎51/AVR/STM32 Driver,Provide initialization code ◎2.8 inch SPI LCD module, without touch only 4 IO driver, with touch only ◎9 IO driver, resolution 240*320 With
-
...Module Product Description Manufacturer Siemens Application Petrochemical Technology Model Number Simatic 6ES7131-6BFOO-OAAO Model Series Simatic 6ES Series Description Simatic ET 200SP, Digital Input Module, DI 8x 24 V DC Basic Type Digital Input Module Classification Electronics Condition New in Box, Original Warranty One Year Country/Region of Country Germany Simatic IO-Link...
...Module Product Description Manufacturer Siemens Application Petrochemical Technology Model Number Simatic 6ES7131-6BFOO-OAAO Model Series Simatic 6ES Series Description Simatic ET 200SP, Digital Input Module, DI 8x 24 V DC Basic Type Digital Input Module Classification Electronics Condition New in Box, Original Warranty One Year Country/Region of Country Germany Simatic IO-Link... more
Brand Name:Siemens
Model Number:6ES7131-6BF00-0AA0
Place of Origin:Germany
VDE High Power IGBT Module 6ES7131-6BF00-0AA0 Digital Input Module
-
...Module The Data Highway Plus network supports messaging between devices. The remote IO-Link connects to remote I/O chassis and other intelligent devices. 1756-EN2F module supports messaging between devices on DH+™ networks. The remote I/O functionality enables the module to act as a scanner for transferring digital and block transfer data to and from remote I/O devices. 1756-EN2T/B module...
...Module The Data Highway Plus network supports messaging between devices. The remote IO-Link connects to remote I/O chassis and other intelligent devices. 1756-EN2F module supports messaging between devices on DH+™ networks. The remote I/O functionality enables the module to act as a scanner for transferring digital and block transfer data to and from remote I/O devices. 1756-EN2T/B module... more
Brand Name:ALLEN BRADLEY
Model Number:1756-EN2F
Place of Origin:USA
ALLEN BRADLEY 1756-EN2F ControlLogix Ethernet 10-100M Interface Module
-
CC-PDIL01 PWA MODULE , DI 24V IO G3 CE CC Digital Input 24 volts DC Ironman Technology Co.,LTD About us: We specializes in automation parts and industrial controls, PLCS,DCS,Module/Board,Power supply,Controller, etc.We maintains an inventory of new and ...
CC-PDIL01 PWA MODULE , DI 24V IO G3 CE CC Digital Input 24 volts DC Ironman Technology Co.,LTD About us: We specializes in automation parts and industrial controls, PLCS,DCS,Module/Board,Power supply,Controller, etc.We maintains an inventory of new and ... more
Brand Name:Honeywell
Model Number:51304419-150
Place of Origin:USA
MC-IOLX02 Honeywell 51304419-150 I/0 PWA IOP FIBER OPTIC CC I/O LINK CARD
-
...Module NX-AD4203 13 Bit Analog Input Unit Specifications I/O system NX I/O Bus Type of module Analog I/O Number of analog inputs 8 Temperature input type None Linear analog input type 4 to 20 mA Resolution of the analog inputs 13 Bit Input circuit type Single-ended Number of analog outputs 0 Linear analog output type None Conversion time 2 ms/unit Signal processing Free running IO link...
...Module NX-AD4203 13 Bit Analog Input Unit Specifications I/O system NX I/O Bus Type of module Analog I/O Number of analog inputs 8 Temperature input type None Linear analog input type 4 to 20 mA Resolution of the analog inputs 13 Bit Input circuit type Single-ended Number of analog outputs 0 Linear analog output type None Conversion time 2 ms/unit Signal processing Free running IO link... more
Brand Name:Omron
Model Number:NX-AD4203
Place of Origin:Japan
8 Points Omron PLC Module NX-AD4203 13 Bit Analog Input Unit
-
...Module Product Description: The product integrates LCD1602 LCD monitors, RGB LED, and five key buttons (Up / Down / Left / Right / OK to select). Due to limited resources PI IO on the inside of the product also incorporates a grain of IIC interface expansion chips, and PI links...
...Module Product Description: The product integrates LCD1602 LCD monitors, RGB LED, and five key buttons (Up / Down / Left / Right / OK to select). Due to limited resources PI IO on the inside of the product also incorporates a grain of IIC interface expansion chips, and PI links... more
Brand Name:OEM
Model Number:OKY4004-1
Place of Origin:Guangdong China (Mainland)
Blue Screen LCD 1602 RGB Keypad Shield for RPI 1602 LCD Display Module
-
...Module One Year Warranty Specifications I/O system NX I/O Bus Type of module Analog I/O Number of analog inputs 8 Temperature input type None Linear analog input type 4 to 20 mA Resolution of the analog inputs 13 Bit Input circuit type Single-ended Number of analog outputs 0 Linear analog output type None Conversion time 2 ms/unit Signal processing Free running IO link...
...Module One Year Warranty Specifications I/O system NX I/O Bus Type of module Analog I/O Number of analog inputs 8 Temperature input type None Linear analog input type 4 to 20 mA Resolution of the analog inputs 13 Bit Input circuit type Single-ended Number of analog outputs 0 Linear analog output type None Conversion time 2 ms/unit Signal processing Free running IO link... more
Brand Name:Omron
Model Number:NX-AD4203
Place of Origin:China
8 Points Omron PLC Module NX-AD4203 13 Bit Analog Input Unit
-
X20PS8002 B&R X20 IO modules for the X20 hub system. It is power supply module, for standalone hub and compact link selector. Accessories is X20TB12, which is the X20 terminal blok,with 12-pin,20 VDC keyed Product information description 1 Supply for X20 ...
-
... by General Electric as a part of the Mark V series used in gas turbine control systems. The ACNA terminal board serves as the connection for the ARCNET data link between the main controller, IOS, protection module, and mark V turbine
... by General Electric as a part of the Mark V series used in gas turbine control systems. The ACNA terminal board serves as the connection for the ARCNET data link between the main controller, IOS, protection module, and mark V turbine more
Brand Name:GE
Model Number:GE Mark V DS200ACNAG1A - ARCNET LAN Connection Board
Place of Origin:USA
GE Mark V DS200ACNAG1A - ARCNET LAN Connection Board
-
...70℃ operating range and special high-temperature resistance for continuous use in extreme conditions Optional IO alarm input/output for linking door status, braking, and oil cut-off Built-in WIFI module for easy configuration via test app Supports TTS