• China GFUVE Alternating Current Clamp On Current Transformer Ratio 500A / 5V 2.5 Meter Cable factory
    ...Current Clamp On Current Transformer Ratio 500A / 5V 2.5 Meter Cable The GFUVE Q40-2 Split Core Current Sensor has high frequency available for oscilloscope, excellent linearity performance. The distinct jaw shapes to be used for hooking or prying around the conductor. In electrical and electronic engineering, a current clamp or current... more
    Brand Name:GFUVE
    Model Number:Q40-2
    Place of Origin:China

    GFUVE Alternating Current Clamp On Current Transformer Ratio 500A / 5V 2.5 Meter Cable

  • China Transformer Ratio Tester HYBC-901 factory
    ...single phase transformer or CT/PT 4 Voltage ratio error calculation 5 Current transformer ratio measurement 6 Excitation current measurement in ratio testing 7 Reproduction the AC test voltage from power source to reduce the effects of bad power source 8 more
    Brand Name:Huaying
    Place of Origin:Wuhan,Hubei,China
    Price:email whhy818@163.com

    Transformer Ratio Tester HYBC-901

  • China Single phase Split Core LV Current Transformers & Ring Core Current Transformer factory
    ... metering,submetering applications,which hasSmall size,easy installation,it is safer and portable than other current transformer. Drawing Size Model I.D. Ratio Rated Amps Accuracy YM-SCT-T06 6mm 1000:1 1, 5,10, 15, 20, 0.5 , 1.0 YM -SCT-T10 10mm ... more
    Brand Name:YOMIN
    Model Number:YM-SCT-T06
    Place of Origin:Zhejiang , China ( Mainland )

    Single phase Split Core LV Current Transformers & Ring Core Current Transformer

  • China Energy Meter Ring Type Current Transformer DC Immunity Multi Ratio Output factory
    ... and nice outline. 3. Flexible wires as primary.Can connect types of terminals. 4. Linear output with accurate current. Can realize for multi ratio output. 5. DC immunity. 6. Encapsulated by mold Injection of environmental plastic. Anti-erosion and more
    Brand Name:Chuangyin
    Place of Origin:Shenzhen
    Certification:KEMA,CE,SGS,TUV,UL

    Energy Meter Ring Type Current Transformer DC Immunity Multi Ratio Output

    Shenzhen Chuangyin Co., Ltd.
    [Guangdong,China]
  • China GENY Current Transformer Test Set 35kv 600A Current Transformer Testing Equipment factory
    ... 35kv / 600A Current Transformer Description: The YCCTR-9901 High-Voltage Current Transformer Turn-Ratio Test Set is meticulously crafted for precise on-line evaluation of turn ratios in current transformers rated at up to 10kV. This innovative system more
    Brand Name:GENY
    Model Number:YCCTR-9901
    Place of Origin:China

    GENY Current Transformer Test Set 35kv 600A Current Transformer Testing Equipment

  • China Split Core 500A Current Transformer Meter Measuring Components factory
    ...Current Split Core Current Transformer 1.Main Features: ● 500A Split Core Current Transformer ● High Reliability via High Accuracy ● Easy Assembly,"0" Cost "0" Destroy ● Well-matched to Measuring & Control Unit 2.Technical Parameters: Main Parameter Item KCT-36-20 Rated primary Current 500A Ratio 3000:1 Voltage Insulation AC >3000V Accuracy (ratio... more
    Brand Name:IVY
    Model Number:500A-Open Core CT
    Place of Origin:Zhejiang

    Split Core 500A Current Transformer Meter Measuring Components

    IVY METERING CO.,LTD
    [Shanghai,China]
  • China Anti Magnetic Current Transformer Clamp Type With 200:1 Coil Ratio factory
    ...6kA Mainly using for: Clamp-on current transformer Clip on current transformer Current transformer clamp Current transformer Technial index notes Testing current: 100mA to 6, 000A Accuracy class is divided into 0.1, 0.2, 0.5 and 1.0 grade Primary current: more
    Brand Name:ERFA
    Model Number:CT022
    Place of Origin:China

    Anti Magnetic Current Transformer Clamp Type With 200:1 Coil Ratio

  • China Acrel AKH-0.66/K-Φ Open Split Core Current Transformer Ac Current Clamp Three Phase Current Transducer factory
    ... and they can help to measure the current or protect the equipment. Type Rated current ratio Accuracy class Circle diameter (mm) 0.5 class 1 class K-Φ24 (150-200)A/5(1)A 1 1 Φ24 (250-300)A/5(1)A 1.5 1 K-Φ36 (300-... more
    Brand Name:Acrel
    Model Number:AKH-0.66/K-Φ
    Place of Origin:China

    Acrel AKH-0.66/K-Φ Open Split Core Current Transformer Ac Current Clamp Three Phase Current Transducer

  • China Customizable Split Core Current Transformer , Clamp Type Current Transformer factory
    ...Current Transformer with Current Range 100mA to 3000A Single-phase Current Test SCTK691/2 series retro-fit (split-core) current transformer has been specially designed to facilitate their installation in new or already existing net works. They may be installed without opening any cable or bus-bar circuit. It can save time and the installation costs. Features: Turns ratio... more
    Brand Name:Shinhom
    Model Number:SCTK691/2 Series
    Place of Origin:China

    Customizable Split Core Current Transformer , Clamp Type Current Transformer

  • China LZZW-10Q 10kv Case Resin Epoxy Current Transformer factory
    ...Current Transformer LZZW-10Q medium voltage current transformers are designed in 10kV and below AC systems of 50Hz or 60Hz for measuring and protection purposes. The products meet the standards IEC60044-1, IEC61869-2 and ANSI/IEEE C57.13. 2. Specification rated transformation ratio(A) Accuary classes combination rated output(VA) (ALF) (FS) short-time thermal current Ith(kA/S) rated dynamic current... more
    Brand Name:XG
    Model Number:LZZW-10
    Place of Origin:XIAN,CHINA

    LZZW-10Q 10kv Case Resin Epoxy Current Transformer

  • China EE10 Miniature Current Transformer DW5523 Low Voltage Current Transformer factory
    ... current and secondary current or primary current and ratio as per your requirements. For example if the energy meter is 5(80)A, you may need a current transformer with current to 80A or 100A. (2) Please specify the accuracy as per secondary circuit or more
    Brand Name:Dowis
    Model Number:EE10
    Place of Origin:CN

    EE10 Miniature Current Transformer DW5523 Low Voltage Current Transformer

  • China 75A 100A 150A output 0.333v 5A split core current transformer current sensor for meter and energy system factory
    ...current transformer : Model No 1 :GWCTSA010 Ratio : 3000:1 Rated input: 5A 10A 20A 50A 75A Accuracy class: 1.0s 3.0s Rated primary current:120A Protection: 5 times protection ,10 times protection like 25A 50A 100A 200A 250A 385A 500A 750A Model No.2 :GWCTSA016 Ratio :3000:1 Rated input: 75A 100A 150A Accuracy class: 0.5 1.0S Rated accuracy limit primary current... more
    Brand Name:grewin
    Place of Origin:Tianjin, China
    Certification:CE ROHS

    75A 100A 150A output 0.333v 5A split core current transformer current sensor for meter and energy system

  • China IEC 61869-2 Current Transformer Testing Equipment For Ratio Error And Phase Displacement Test factory
    ... error and phase displacement of current transformers. Standard: IEC 61869-2 Instrument transformers - Part 2: Additional requirements for current transformers Current Transformer Testing Equipment configuration: Current transformer tester, the product is more
    Brand Name:HongCe
    Model Number:DL-30
    Place of Origin:China

    IEC 61869-2 Current Transformer Testing Equipment For Ratio Error And Phase Displacement Test

  • China Wide Current Range Isolation Current Transformer Three Phase 200A RS485 Port factory
    ...Current Transformer wide current range 200A ratio 1:1 KE6323-200 Isolation current transformer KE6323-200 Isolation current transformer (ICT) is used for the test of I-P close link meter. When test the three phase meters, the voltage and current circuit cannot be separated, it needs to isolate the voltage and current... more
    Brand Name:KRE
    Model Number:KE6323-200
    Place of Origin:China

    Wide Current Range Isolation Current Transformer Three Phase 200A RS485 Port

  • China VT Voltage Transformer Test Equipment For CT Current Transformer factory
    ...current transformer: Excitation curve and parameters test Turns ratio test Ratio and phase error test Polarity mark check Winding resistance measurement Secondary loop burden measurement Error line curve test for protection CT Transient CT parameters test CT nameplate guess Saturation hysteresis loop curve measurement Tests for Potencial Transformer: Turns ratio test Ratio... more
    Brand Name:AI
    Model Number:CPT-I
    Place of Origin:China

    VT Voltage Transformer Test Equipment For CT Current Transformer

  • China DM-20 5/5A-300/5A DM current transformer din rail toroidal transformer factory
    ...Current transformer: Primary current: Secondary current: Standard approval: Maximum voltage: Frequency: Rated load: Class: Short-time thermal current: Rated security coefficient: 5A-300A 5A,1A VDE0414,BS7626,IEC60044-1 0.72/3KV 50-60Hz 1.5VA,2.5VA,5VA 0.5,1.0 Ith=60×Ih FS<5 Type Current ratio... more
    Brand Name:SUCHEN
    Model Number:CN-DM-20
    Place of Origin:China

    DM-20 5/5A-300/5A DM current transformer din rail toroidal transformer

  • China CPT-III Single Phase or Three Phase Portable Current Transformer Tester factory
    ...Current Transformer Tester Application: Tests for current transformer: Excitation curve and parameters test Turns ratio test Ratio and phase error test Polarity mark check Winding resistance measurement Secondary loop burden measurement Error line curve test for protection CT Transient CT parameters test CT nameplate guess Saturation hysteresis loop curve measurement Tests for voltage transformer: Turns ratio more
    Model Number:CPT-III
    Place of Origin:China
    Certification:ISO9001

    CPT-III Single Phase or Three Phase Portable Current Transformer Tester

  • China Audio Clamp On Current Transformer Ct 0.1A 2000t Ratio factory
    Split Core Current Transformer Clamp On Type The HM-CTC1535 is a high performance AC clamp on Current transformer with excellent transformation and low phase shift. The high quality magnetic core and uniform windings provide for accurate measurements up ... more
    Brand Name:HEMEI
    Model Number:HM-CTC1535
    Place of Origin:China

    Audio Clamp On Current Transformer Ct 0.1A 2000t Ratio

Tell “current transformer ratios” Suppliers Your Requirement
*E-mail:
* Message:
Characters Remaining: (0/3000)
Inquiry Cart 0