...10kA Residual Current Circuit Breaker RCCB Type S Selective time delay for Short-Circuit Protection VKL11 Residual Current Circuit Breaker RCCB Type S Selective time delay 1. General 1.1 RCCB Function Control electric circuits. Protect people against indirect contacts and additional protection against direct contacts. Protect installations against fire hazard due to insulation faults. Residual current circuit breakers...
...10kA Residual Current Circuit Breaker RCCB Type S Selective time delay for Short-Circuit Protection VKL11 Residual Current Circuit Breaker RCCB Type S Selective time delay 1. General 1.1 RCCB Function Control electric circuits. Protect people against indirect contacts and additional protection against direct contacts. Protect installations against fire hazard due to insulation faults. Residual current circuit breakers... more
Brand Name:HAROK
Model Number:VKL11
Place of Origin:CHINA
-
...10KA F202 Residual Current Circuit Breake RCCB 1. High Quality. 2. W CE certificate 3. Very Comparative price 4. 2P Kampa Wholesales F202 10KA F202 Residual Current Circuit Breaker RCCB 1.Main technical specifications Number of poles 2P Breaking capacity 6KA Rated current(A) 16,25,40,63,80,100A Rated voltage(V) AC 2P 230/240V 4P 400/415V Rated residual operating current(mA) 30,100,300,500mA Rated residual...
...10KA F202 Residual Current Circuit Breake RCCB 1. High Quality. 2. W CE certificate 3. Very Comparative price 4. 2P Kampa Wholesales F202 10KA F202 Residual Current Circuit Breaker RCCB 1.Main technical specifications Number of poles 2P Breaking capacity 6KA Rated current(A) 16,25,40,63,80,100A Rated voltage(V) AC 2P 230/240V 4P 400/415V Rated residual operating current(mA) 30,100,300,500mA Rated residual... more
Brand Name:Kampa
Model Number:F202
Place of Origin:Zhejiang, China
Kampa Wholesales F202 10KA F202 Residual Current Circuit Breaker RCCB
-
... with the standards of IEC61009.It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunkline.Thus it is suitable to avoid the shock hazard and fire caused by earth leakage.It can be used in circuits up to
... with the standards of IEC61009.It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunkline.Thus it is suitable to avoid the shock hazard and fire caused by earth leakage.It can be used in circuits up to more
Brand Name:SONTUOEC ,SONTUOC,STUOEC, WZSTEC
Model Number:STRO9-40L
Place of Origin:Wenzhou, China
Din Rail 18mm 10KA 6KA Residual Current Circuit Breaker
-
... currents, thus ensuring protection against electric shocks caused by indirect contact. These devices must be used in series with MCBs or fuses to protect them from the potentially damaging ...
-
...residual current circuit breaker RCCB Rated resudual operating current In(A):0.03,0.1,0.3,0.5 Rated conditional short-circuit current Inc:10kA Terminal Connection Height:21mm Electro-machanical endurance:4000 cycles Connection capacity:Rigid conductor 25mm2 Connection terminal:Screw terminal type In/A I△n/A Residual Current...
...residual current circuit breaker RCCB Rated resudual operating current In(A):0.03,0.1,0.3,0.5 Rated conditional short-circuit current Inc:10kA Terminal Connection Height:21mm Electro-machanical endurance:4000 cycles Connection capacity:Rigid conductor 25mm2 Connection terminal:Screw terminal type In/A I△n/A Residual Current... more
Brand Name:SEFIE
Model Number:SFL6-63
Place of Origin:WenZhou,China
240V Residual Current Circuit Breaker RCCB / 2 Pole Circuit Breaker IP20
-
... of230V(1P+N) or 400V(3P+N),and rated current of 100A.In case of electric shock or electric leakage current exceeds the specified value, the residual current circuit breaker can switch off the fault circuit in a very short time, protecting the safety of
-
...Circuit Breaker RCBO 10kA Leakage Short Circuit Over Load Protection Function: ♦ Control electric circuits ♦ Protect people against indirect contacts and additional protection against direct contacts ♦ Protect installations against fire hazard due to insulation faults ♦ Residual current circuit breakers...
...Circuit Breaker RCBO 10kA Leakage Short Circuit Over Load Protection Function: ♦ Control electric circuits ♦ Protect people against indirect contacts and additional protection against direct contacts ♦ Protect installations against fire hazard due to insulation faults ♦ Residual current circuit breakers... more
Brand Name:YOKG
Model Number:PR8HM
Place of Origin:China
Household 2 Pole Residual Current Circuit Breaker 10kA Short Circuit Overload Protection
-
Europe Standard certificate residual current circuit breaker/rccb #detail_decorate_root .magic-0{border-bottom-style:none;border-bottom-color:#53647a;font-family:Arial,Helvetica;font-size:18px;color:#fff;background-color:#b9cae9;font-style:normal;border...
Europe Standard certificate residual current circuit breaker/rccb #detail_decorate_root .magic-0{border-bottom-style:none;border-bottom-color:#53647a;font-family:Arial,Helvetica;font-size:18px;color:#fff;background-color:#b9cae9;font-style:normal;border... more
Brand Name:SUNTREE
Model Number:SCB8LT-100H
Place of Origin:Zhejiang, China
Europe 10KA RCCB Residual Current Circuit Breaker
-
...) is an electrical wiring device that disconnects a circuit whenever it detects that the electric current is not balanced between the energized conductor and the return neutral conductor. Such an imbalance may indicate current leakage through the body of a
...) is an electrical wiring device that disconnects a circuit whenever it detects that the electric current is not balanced between the energized conductor and the return neutral conductor. Such an imbalance may indicate current leakage through the body of a more
Brand Name:KRIPAL
Model Number:UKL1
Place of Origin:China
Micro Circuit Breaker Earth Leakage Residual Current Circuit Breaker
-
...A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 63A.When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to protect human safety and prevent the
...A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 63A.When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to protect human safety and prevent the more
Brand Name:Fenigal/OEM
Model Number:FGID
Place of Origin:China
Model ID 63A RCCB Residual Current Circuit Breaker 30mA 2P 4P
-
...Residual Current Circuit Breaker Product Description: Type B RCDs. Protection against shock and fire hazards during EV charging. Requires detection of AC and DC residual fault currents. This can be achieved by the use of dedicated RCDs, or by a combination of DC and/or AC residual current...
...Residual Current Circuit Breaker Product Description: Type B RCDs. Protection against shock and fire hazards during EV charging. Requires detection of AC and DC residual fault currents. This can be achieved by the use of dedicated RCDs, or by a combination of DC and/or AC residual current... more
Brand Name:HEIU
Model Number:EKL1-63
Place of Origin:China
RCCB 4 Pole Residual Current Circuit Breakers 40A 63A 230V 400V 0.03mA
-
...Electrical Miniature Circuit Breakers DC MCB FPV-125 high breaking capacity circuit breaker is specially for solar PV system. The current is form 63A to 125A and voltage up to 1000VDC. Standard according to IEC/EN60947-2. Specifications Rated current 63,80...
...Electrical Miniature Circuit Breakers DC MCB FPV-125 high breaking capacity circuit breaker is specially for solar PV system. The current is form 63A to 125A and voltage up to 1000VDC. Standard according to IEC/EN60947-2. Specifications Rated current 63,80... more
Brand Name:FEEO
Model Number:FPV-125
Place of Origin:China
550VDC 125A 2P Residual Current Circuit Breaker
-
RKN Series Micro-Broken Circuit Breaker LG/LS Electric Small Protector RKN-1P+N/2P/3P/4P Circuit Breaker Metso electronics is a provider of electronic components, design and development services for electronic manufacturing enterprises. The supply chain...
RKN Series Micro-Broken Circuit Breaker LG/LS Electric Small Protector RKN-1P+N/2P/3P/4P Circuit Breaker Metso electronics is a provider of electronic components, design and development services for electronic manufacturing enterprises. The supply chain... more
Brand Name:JULUN
Model Number:RKN 4P C40A 30mA;RKN 4P C63A 30mA
Place of Origin:CHINA
Micro Broken Residual Current Circuit Breaker LG / LS Electric Small Protector RKN
-
... protection (RCBO) in four modules for the protection against short-circuit currents, overload, earth fault currents, indirect contacts, additional protection against direct contacts (30 mA versions). The new series is suitable for installation in IT
... protection (RCBO) in four modules for the protection against short-circuit currents, overload, earth fault currents, indirect contacts, additional protection against direct contacts (30 mA versions). The new series is suitable for installation in IT more
Brand Name:ABB
Model Number:2CSR256147R1084 DS203NC C8 A30 230V
Place of Origin:IT ; FI
2CSR256147R1084 Current Circuit Breaker DS203NC C8 A30 230V 3P+N
-
...Circuit Breaker 63A Model NO.: SBS-H-63 Features: Non-polarity bidirectional protection for circuit; Overload protection; Short Circuit Protection High breaking capacity up to 6KA Technical Data Ui 1000V DC Ue 250/500/750/1000V DC Ie 10~63A Product Pictures: Company Profile NeoPower is dedicated to high-voltage/ high-current...
...Circuit Breaker 63A Model NO.: SBS-H-63 Features: Non-polarity bidirectional protection for circuit; Overload protection; Short Circuit Protection High breaking capacity up to 6KA Technical Data Ui 1000V DC Ue 250/500/750/1000V DC Ie 10~63A Product Pictures: Company Profile NeoPower is dedicated to high-voltage/ high-current... more
Brand Name:Neopower
Model Number:SBS-H-63
Place of Origin:China
6KA Electric Circuit Breakers, Non Polarity Miniature Current Circuit Breaker
-
...Circuit Breaker Thermal Switch Mccb Usage and scope of application The design of CNSV series of MCCB reflects the latest current limiting principle and manufacturing technology, characterized by compact structure, full modularization, high breaking, and zero arcover. Its rated insulation voltage is 690V, rated operating voltage is AC50/60Hz, 440V and below, rated current...
...Circuit Breaker Thermal Switch Mccb Usage and scope of application The design of CNSV series of MCCB reflects the latest current limiting principle and manufacturing technology, characterized by compact structure, full modularization, high breaking, and zero arcover. Its rated insulation voltage is 690V, rated operating voltage is AC50/60Hz, 440V and below, rated current... more
Brand Name:QK
Model Number:CNS
Place of Origin:China
Overload Remote Miniature Current Circuit Breaker Large Current Carrying Capacity
-
Product Description Product Name Waterproof On-Off Switch Ignition Protected Circuit Breaker with RED Button Manual Reset Types Single Pole Thermal Type Breakers Volt Rating 48V dc Amp Rating 30A Interrupting Rating 5KA@32VDC, 3KA@48VDC Body Material Black...
Product Description Product Name Waterproof On-Off Switch Ignition Protected Circuit Breaker with RED Button Manual Reset Types Single Pole Thermal Type Breakers Volt Rating 48V dc Amp Rating 30A Interrupting Rating 5KA@32VDC, 3KA@48VDC Body Material Black... more
Model Number:E99-30
Place of Origin:China
Minimum Order Quantity:100
30 Amp High Current Circuit Breakers E99 48V With Manual Reset Switch