... PN Ib(In(A)) Imax(A) Secondary Current(mA) Accuracy(class) Burden(Ω) IVY-CS-01-20A-C500 5 20 5 0.1 10 Current Error % Phase Error ±(') 5%I 20%I 100%I 400%I 800%I Imax 5%I 20%I 100%I 400%I 800%I Imax ≤0.10 ≤0.10 ≤0....
... PN Ib(In(A)) Imax(A) Secondary Current(mA) Accuracy(class) Burden(Ω) IVY-CS-01-20A-C500 5 20 5 0.1 10 Current Error % Phase Error ±(') 5%I 20%I 100%I 400%I 800%I Imax 5%I 20%I 100%I 400%I 800%I Imax ≤0.10 ≤0.10 ≤0.... more
Brand Name:IVY
Model Number:IVY-CS-01-20A-C500
Place of Origin:Zhejiang
-
Current Sensor Self-Supplying Power Supply Device For Underground Min Application: Power online monitoring system (cable status monitoring, high-voltage power transmission monitoring); outdoor smart switchgear; power wireless temperature measurement sys...
Current Sensor Self-Supplying Power Supply Device For Underground Min Application: Power online monitoring system (cable status monitoring, high-voltage power transmission monitoring); outdoor smart switchgear; power wireless temperature measurement sys... more
Brand Name:HEMEI
Model Number:HMCQDCT45-2001
Place of Origin:China
Underground 20A Current Transformer Power Supply Epoxy Resin 3.8W
-
... Parameter list: Primary current Secondary current class 20A 20mA 0.5,0.2 20A 10mA 0.5,0.2 30A 30mA 0.5,0.2 30A 15mA 0.5,0.2 30A 10mA 0.5,0.2 40A 40mA 0.5,0.2 40A 20mA 0.5,0.2 50A 50mA 0.5,0.2 50A 25mA 0.5,0.2 ...
... Parameter list: Primary current Secondary current class 20A 20mA 0.5,0.2 20A 10mA 0.5,0.2 30A 30mA 0.5,0.2 30A 15mA 0.5,0.2 30A 10mA 0.5,0.2 40A 40mA 0.5,0.2 40A 20mA 0.5,0.2 50A 50mA 0.5,0.2 50A 25mA 0.5,0.2 ... more
Brand Name:Metrum
Model Number:KH-16
Place of Origin:China
16mm Current Transformer 100A 0.2 Class With Lead Output
-
... in tiny currents measurement, with a highly galvanic isolation between primary and secondary circuit. Widely used in leakage monitoring systems, signaling systems and the current difference measurement etc. Model ACST011A-20A-10mA Rated input current 0
... in tiny currents measurement, with a highly galvanic isolation between primary and secondary circuit. Widely used in leakage monitoring systems, signaling systems and the current difference measurement etc. Model ACST011A-20A-10mA Rated input current 0 more
Brand Name:Shinhom
Model Number:CT Series
Place of Origin:China
PCB Mounted 20A Current Sense Transformer Epoxy Encapsulation
-
...20A/20mA class 0.5 Current transformer for working frequency 50-400Hz , energy meter, power transducer Features: 1. Good voltage separation ability and insulation property 2. It is applicable for working frequency 50-400Hz 3. With burnt-resistant PBT case and epoxy resin, current transformer...
...20A/20mA class 0.5 Current transformer for working frequency 50-400Hz , energy meter, power transducer Features: 1. Good voltage separation ability and insulation property 2. It is applicable for working frequency 50-400Hz 3. With burnt-resistant PBT case and epoxy resin, current transformer... more
Brand Name:Greenfair
Model Number:Current transformer CT07
Place of Origin:China
Energy Meter Electronic Current Transformer 50 - 400Hz Power Transducer
-
...current transformer : Model No 1 :GWCTSA010 Ratio : 3000:1 Rated input: 5A 10A 20A 50A 75A Accuracy class: 1.0s 3.0s Rated primary current:120A Protection: 5 times protection ,10 times protection like 25A 50A 100A 200A 250A 385A 500A 750A Model No.2 :GWCTSA016 Ratio :3000:1 Rated input: 75A 100A 150A Accuracy class: 0.5 1.0S Rated accuracy limit primary current...
...current transformer : Model No 1 :GWCTSA010 Ratio : 3000:1 Rated input: 5A 10A 20A 50A 75A Accuracy class: 1.0s 3.0s Rated primary current:120A Protection: 5 times protection ,10 times protection like 25A 50A 100A 200A 250A 385A 500A 750A Model No.2 :GWCTSA016 Ratio :3000:1 Rated input: 75A 100A 150A Accuracy class: 0.5 1.0S Rated accuracy limit primary current... more
Brand Name:grewin
Place of Origin:Tianjin, China
Certification:CE ROHS
75A 100A 150A output 0.333v 5A split core current transformer current sensor for meter and energy system
-
...replace DC Wheatstone Bridge and double-arm Bridge. It adopts the advanced starting power constant current source technology, uses four digit and half LCD display value and three digit and half LCD displays the ambient temperature or test current value, it
...replace DC Wheatstone Bridge and double-arm Bridge. It adopts the advanced starting power constant current source technology, uses four digit and half LCD display value and three digit and half LCD displays the ambient temperature or test current value, it more
Brand Name:Delta
Model Number:WRT
Place of Origin:China Mainland
WRT Portable 5A 10A 20A 40A Transformer DC Winding Resistance Tester
-
...20A/1V SCT013-020 AC Current Sensor Module Split Core Current Transformer Description Current transformers are sensors that are used for measuring alternating current. They are particularly useful for measuring whole building electricity consumption (or generation for that matter). Like any other transformer, a current transformer...
...20A/1V SCT013-020 AC Current Sensor Module Split Core Current Transformer Description Current transformers are sensors that are used for measuring alternating current. They are particularly useful for measuring whole building electricity consumption (or generation for that matter). Like any other transformer, a current transformer... more
Brand Name:OKYSTAR
Model Number:OKY3318
Place of Origin:Guangdong China(Mainland)
Blue 3.5mm 20A/1V SCT013-020 AC Current Sensor Module Split Core Current Transformer
-
1. Product Name: CT PT Analyzer HYVA-402 2. Equipment Description: HYVA-402 can finish: CT/PT volt-ampere characteristic curve test, CT/PT Polarity test, CT/PT Transformation ratio test, automatically calculate error curve of any CT point. 3.Technical ...
1. Product Name: CT PT Analyzer HYVA-402 2. Equipment Description: HYVA-402 can finish: CT/PT volt-ampere characteristic curve test, CT/PT Polarity test, CT/PT Transformation ratio test, automatically calculate error curve of any CT point. 3.Technical ... more
Brand Name:Huaying
Model Number:Huaying Series
Place of Origin:Wuhan Hubei China
Current Transformer Tester
-
CT PT Analyzer HYVA-402 HYVA-402 can finish: CT/PT volt-ampere characteristic curve test, CT/PT Polarity test, CT/PT Transformation ratio test, automatically calculate error curve of any CT point. Input voltage Output scope Measuring scope Measuring degree...
CT PT Analyzer HYVA-402 HYVA-402 can finish: CT/PT volt-ampere characteristic curve test, CT/PT Polarity test, CT/PT Transformation ratio test, automatically calculate error curve of any CT point. Input voltage Output scope Measuring scope Measuring degree... more
Brand Name:Huaying
Place of Origin:Wuhan,Hubei,China
Certification:ISO CE
Current Transformer Testing Equipment China Maker
-
Main View Top View Customer use case:
-
...main products are high-voltage current-limiting fuses with voltage grades ranging from 3.6 kv to 40.5 kv. Products, divided into transformer, motor and voltage transformer and capacitor protection for high-voltage current-limiting fuses and a full range of
-
20A Transformer Winding Ohmmeter Model: TWO-120S Maximum 20A current for measuring winding resistance of power transformer Transformer Winding Ohmmeter is designed to measure the dc resistance of all types of magnetic windings accurately. It can test transformers and rotating machine windings and perform low-current...
20A Transformer Winding Ohmmeter Model: TWO-120S Maximum 20A current for measuring winding resistance of power transformer Transformer Winding Ohmmeter is designed to measure the dc resistance of all types of magnetic windings accurately. It can test transformers and rotating machine windings and perform low-current... more
Brand Name:HAOMAI
Model Number:TWO-120S
Place of Origin:China
20A IEC61326 DC Insulation Tester , 13kg Winding Resistance Meters
-
Product Description Model KCT-10 Current Ratio 5A/2.5mA 20A/10mA 60A/20mA 75A/25mA 1-75A/0.333V Primary Current (A) 5A 20A 50A 75A 1-75A Max. Current (A) 60A 60A 75A 75A 1-75A Output 2.5mA 10mA 20mA 25mA 0.333V Load Resistance (Ω) 400Ω 100Ω 50Ω 20Ω / Turns...
-
Factory Wholesale Price Xrnp and Xrnt Series High Voltage Current Limiting Fuse Backup Fuse Product Description High Voltage Current LImited Back Up Fuse Protect the Power Equipment XRNT Type: 12kV, 24kV and 35kV, 3A...315A For Gas And Air Insulated Switch...
-
... EE4.2, EE5, EE8.3 ,EF12.6 are available MODEL IND. TOL. SCHEMATIC LETTER DCR MAX. (Ω) MAX. RATED DC CURRENT (A) (1) SATURATING CURRENT (A) (2)
-
...current 250V 380V 16A 20A 25A 30A BRI Pump Motor Transformer Thermostat Temperature Switch Thermal Prot Rating Current 16A 25A 35A Rating Voltage 250V 380V Certificate ROHS Reset Type Automatic Reset Application Big Power Appliances Life Cycle >2000 Times Material Metel Case Contact Form Normally Closed Description BRI thermal protector with high-current...
...current 250V 380V 16A 20A 25A 30A BRI Pump Motor Transformer Thermostat Temperature Switch Thermal Prot Rating Current 16A 25A 35A Rating Voltage 250V 380V Certificate ROHS Reset Type Automatic Reset Application Big Power Appliances Life Cycle >2000 Times Material Metel Case Contact Form Normally Closed Description BRI thermal protector with high-current... more
Brand Name:Tianrui
Model Number:BRI
Place of Origin:Guangdong,China
250V 380V 16A 20A 25A 30A BRI Pump Motor Transformer Thermostat Temperature Switch High Current