Home > Electrical Instruments >

Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag

Categories Glass Tube Fuse
Brand Name: AOLITTEL
Model Number: TBP1500A
Certification: UR,C-UR,CQC,VDE,PSE
Place of Origin: CHINA
MOQ: 1000 Pieces
Price: Negotiable
Payment Terms: T/T
Supply Ability: 10,000,000 Pieces Per Month
Delivery Time: 7-10 Days
Packaging Details: Bulk,500pcs/bag,0.6g/pcs
Type: Glass Tube Fuse
Dimension: 4x11mm
Current Rating: 5A
Rated Voltage: 250VAC
Blow: Slow/Time Delay
Cap: Nickel Plated Brass
Body: Glass Tube
Fuse Element: Alloy
Lead Wire: Tin Plated Copper
Operating Temperature: -55℃~+125℃
  • Product Details
  • Company Profile

Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag


Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag


Shortcut info


Product name: glass fuse; rated Voltage: AC 250V; rated current: 5A
Function: slow blow; body Size: 11 x 4mm/ 0. 4' x 0. 15' (LED)
Wire Leads length(each): 27mm/ 1 inch
Color: Clear, Silver Tone; material: glass, alloy


___________________________________________________________Epoxy Coated Photocell 11mm Diameter Photoresistor Light Sensor GM11528 With Light Resistance 10-20 KOhm Download________


Specification


A=250V B=125V

Part

No.

Ampere

Rating

Voltage

Rating

Max Voltage

Drop (mv)

I2TMelting

Integral(A2.S)

TBP0250A250mA250V2400.06
TBP0315A315mA250V2200.09
TBP0400A400mA250V2000.2
TBP0500A500mA250V1900.4
TBP0630A630mA250V1801.0
TBP0800A800mA250V1601.9
TBP1100A1A250V1404.2
TBP1125A1.25A250V1308.7
TBP1160A1.6A250V12010.1
TBP1200A2A250V10020.3
TBP1250A2.5A250V10040
TBP1315A3.15A250V10068
TBP1400A4A250V100100
TBP1500A5A250V100133
TBP1630A6.3A250V100172

Certifications


Voltage Rating

Agency

Ampere Range

Agency File Number

250VUR250mA ~ 5AE340427(JDYX)
C-UR250mA ~ 5AE340427( JDYX7)
CQC250mA ~ 5ACQC16012161227
VDE500mA,1A,1.25A,1.6A,2A,2.5A,3.15A,5A40032053
PSE250mA ~ 5 APending
KTL250mA ~ 5 APending

Standards:In accordance with IEC60127-1, IEC60127-3, GB9364.1, GB9364.3.


Dimension (mm)



Operating Characteristics


% of Ampere Rating(In)

Blowing Time

210%*In2 min Max
275%*In400 ms~10 s
400%* In150 ms~3s

Average Time Current Curves



Installation Recommendations


Propose installation way as following picture.


A.Horizontal installation
B.Vertical installation
C.Vertical installation

Checking and replacing fuses


Procedure


Many electrical devices used in eye care have an externally accessible fuse near the electrical cord (Figure 1) that you can check and replace by following these steps.


Figure 1


  1. Disconnect the device from the electrical system.
  2. Remove the fuse from its holder. In some cases you may need a small screwdriver to unscrew the fuse holder cap.
  3. Look at the fuse wire. If there is a visible gap in the wire or a dark or metallic smear inside the glass then the fuse is blown and needs to be replaced. If you cannot see whether the fuse is blown, follow steps 4 and 5. If the fuse is definitely blown, go to step 6.
  4. Set a multimeter (Figure 2) to the resistance or Ω (Ohms) setting.

Figure 2


5.Place one of the multimeter leads on one end of the fuse. Place the other lead on the other end of the fuse. If the reading is between 0 and 5 Ω (Ohms), the fuse is good. A higher reading indicates a bad or degraded fuse. A reading of OL (Over Limit) definitely means a blown fuse.

6.If the fuse is blown, replace the fuse with one that is exactly the same (see panel). Make sure to note the fuse amperage and voltage ratings, which should be marked on the fuse itself (Figure 3) or on the panel label near the fuse holder. Additionally, note the size and whether it is a slow-blow or a fast-blow type fuse. If there are no markings on the fuse itself or on the equipment you must consult the device's operating manual.

Figure 3


General suggestions


*Always disconnect equipment from electrical power before removing a fuse; not doing so may result in serious injury.
*Always replace a fuse with an identical type, and never substitute a fuse with foil or another object. This could lead to electrocution and fires.
*Keep enough stock of the fuses used in your clinic or hospital. Store each type in separate containers with a label describing the fuse's voltage and amperage, whether it is a fast-blow or slow-blow type, the size, minimum number needed (the minimum stock level), and the models of equipment that use each type of fuse.
*Check your stock of fuses frequently and order more fuses when it reaches the minimum stock level.
If possible, tape a spare fuse to the equipment so that it is available when needed.

Product Tags:

small glass fuses

  

mini glass fuse

  
China Germany VDE 4x11mm Slow Blow Axial Leaded Miniature Time Delay Glass Tube Fuse T5AL250V 5A 250VAC 500PCS Per Bag factory
Send your message to this supplier
 
*From:
*To: Aolittel Technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
You may also be interested in :
Inquiry Cart 0
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    Contact Us Quickly